Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It's a grate service manuals.Have many details and the writing it's so clear.You have all you want in manual,nothing missing,belive me.I'm verry satisfied of this manual.
 ;
Great scanned service manual
Usefull informations.
I will buy again!
Best Regards
 ;
The manual describes this product very good. It has the basic things to know and also a more detailed look. Very well made!
 ;
An excellent document to assist in the repair of my old personal tape player. It includes full circuit diagrams and physical layout drawings and full instructions on disassembly and fault finding.
Well worth the meagre price.
 ;
Very good conversation, Pretty fast Service, wood do it again,
Have paid by Paypal, so i got the Service Manual online after 15 Min.
Very helpfully.
Greeting from Germany,
Hans
AV-29LS AV-29LH
AV-29LX AV-2908TEE
PURITY AND CONVERGENCE ADJUSTMENTS
Note: The final adjustment of CONVERGENCE must be done after the FOCUS adjustment. (CONVERGENCE is changed by FOCUS adjustment.) When makes difference by FOCUS adjustment, should be reconfirming PURITY adjustment.
WEDGE DEFLECTION YOKE
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer. 2. Loosen the retainer screw of the deflection yoke. 3. Remove the wedges. 4. Input a green raster signal from the signal generator, and turn the screen to green raster. � P/C MAGNETS 5. Move the deflection yoke backward. 6. Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig. 2) 7. Adjust the gap between two lugs so that the GREEN RASTER will come into the centre of the screen. (Fig. 3) 8. Move the deflection yoke forward, and fix the position of the deflection yoke so that the whole screen will become green. 9. Insert the wedge to the top side of the deflection yoke so that it will not move. 10. Input a crosshatch signal. 11. Verify that the screen is horizontal.
Short lug Long lug
CRT
P
46
P/C MAGNETS
P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets) Fig. 1
PURITY MAGNETS
12. Input red and blue raster signals, and make sure that purity is properly adjusted.
Bring the long lug over the short lug and position them horizontally.
Fig. 2
(FRONT VIEW)
GREEN RASTER
CENTRE
Fig. 3