Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
The manual was exact the thing that was promised. My old car stereo is working again thanks to the information supplied.
 ;
I PURHASED THIS PRODUCT BECAUSE I WAS HAVING PROBLEMS WITH MY CDR20 HARMAN KARDON RECORDER. WHICH I PURCHASED NEW 12 YEARS AGO. AFTER REVIEWING THE MANUAL, I WAS ABLE TO ADJUST THE TENSIONER IN THE SYSTEM. WORKS LIKE A CHAMP!.
SAVED ME AT LEAST 100.00 WHICH WAS WHAT A SERVICE REPAIR STATION WANTED. GREAT MANUAL EASY TO READ. SPECIALLY AFTER I PRINTED THE PAGES WHICH DEALT WITH MY RECORDER. THANKS A LOT!!!!!!!!
 ;
You can fully trust on this one!
All the schematics are very crear an in one piece per page
 ;
I have never bought a service manual which is as competely readable as this althogh it was a scanned pdf. Thank you for this succesful manual also cheaper than other sites.
 ;
Thanks for a very good and readable servicemanual. Just what I needed as a "dinosaur technician". I really recommmend this site and will come back.
Åsbjörn
AV-36D202 AV-36D302 AV-36D502
ADJUSTMENTS OF PURITY AND CONVERGENCE
Note: The final adjustment of CONVERGENCE must be done after the FOCUS adjustment. (CONVERGENCE is changed by FOCUS adjustment.) When makes difference by FOCUS adjustment, should be reconfirming PURITY adjustment.
WEDGE DEFLECTION YOKE
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer. 2. Loosen the retainer screw of the deflection yoke. 3. Remove the wedges. 4. Input a green raster signal from the signal generator, and turn the screen to green raster. � P/C MAGNETS 5. Move the deflection yoke backward. 6. Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig.2) 7. Adjust the gap between two lugs so that the GREEN RASTER will come into the center of the screen. (Fig.3) 8. Move the deflection yoke forward, and fix the position of the deflection yoke so that the whole screen will become green. 9. Insert the wedge to the top side of the deflection yoke so that it will not move. 10. Input a crosshatch signal. 11. Verify that the screen is horizontal.
Short lug Long lug
CRT
P
46
P/C MAGNETS
P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets) Fig. 1
PURITY MAGNETS
12. Input red and blue raster signals, and make sure that purity is properly adjusted.
Bring the long lug over the short lug and position them horizontally.
Fig. 2
(FRONT VIEW)
GREEN RASTER
CENTER
Fig. 3
32
No. 51798
|
|
 |
> |
|
|