AV-36D503 AV-36D303 AV-36D203
Item RF AGC adjustment
Measuring instrument Remote control unit
Test point
Ad justment part S45 AGC ADJ [V/C(S) mode]
Description 1. Receive the broadcast. 2. Enter to the V/C(S) mode from SERVICE MENU. 3. Select the S45 AGC ADJ item. 4. Press the MUTING key and turn the c olor to off. 5. With the CURSOR key to get the nois e in the screen picture (zero side of setting value). 6. Press the CURSOR key several times and step when noise disappears from the screen. At this time, not to increase the value too much. 7. Change to other channels and make sure that there is no irregularity. 8. Press the MUTING key and get c olor out.
Ad justment item
Variable range
Initial setting value
S45 AGC ADJ
0�127
63
FOCUS adjustment
Signal gener ator
FOCUS VR [In FBT]
1. Receive the crosshatch signal. 2. While looking at the screen, adjust the FOCUS VR to the vertical and horizontal lines will be clear and make fine in a detail. 3. Make sure that the picture is in focus even when the sc reen gets dark ened.
Clear and fine
24