|
There are currently no product reviews.
 ;
Very good scanning quality. All schematics are very legible. Worth every cent !
 ;
Excellent quality, very quick download turnaround, will definately use again.
 ;
This is a awesome quality scan of the original Service Manual for Technics 8099.
Contains the circuit diagram, PCB layout, adjust/tune instructions as well.
Since this is my first buy here, i'm really glad! This site do works as intended/described, it's definitely not scam!
Мои рекомендации! Все мануалы настоящие!
 ;
Good Quality of the File.
You get the normal manual is incudet.
 ;
Very nice and real Service Manual, I didn't thought it actually exist in the real world at all.
1
2
3
4
A
- To reset the settings
When the EEPROM data is damaged due to failure, connect the TP302 to the ground. The initial settings stored in the monitor microcomputer will be automatically written into the EEPROM. Manually, you may adjust all the items on TEST1 and TEST2 modes to the adjustment values shown on the previous page.
- To operate the monitor only (see the adjustment points)
Connect the 14V, 7V and ground lines to the monitor pc board as shown on the wiring diagram. Turn on the power. 1) Apply the video signal to the test point around the center of the pc board. 2) For remote control output confirmation, use the test point near the monitor connector. 3) Confirm that the signal received by the remote control sensor (installed in the monitor) can be obtained at the pin 8 (MOREM) of the CN501.
B
- To operate the power supply unit only
Connect the power cord to the power supply unit. Switch the pin 10 (DSEN) of the CN757 to "L" and the pin 13 (SYSPWR) to "H". Check each power line, video signal, and remote control signal.
C
D
E
F
52 1 2
AVD-W6200/UC
3
4
|