|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I never been disappointed in my dealings with owners-manuals.com
 ;
Excellent printing quality. A complete and very useful manual with all details.
 ;
Even if the PDF is a scan, I can read the information I need.
The price is affordable and the service (mail sending) is very fast.
Thanks ! Regards. William (Fan of Kenwood)
 ;
Very good quality original datasheet!I like this amazing website!!!!!!
 ;
Excellent just what I needed to replace the electrolytic caps and make this old gem a beauty again. Was as scan of the original photocopied service manual.
5
6
7
8
8. In case of method 1: Please go on to step 9. In case of method 2: Perform all automatic adjustments after Tracking Open once, and then close the tracking with the command that is available for RF display. 9. Using torx driver (T2) (GGK1095) , In case of method 1: Turn the skew adjustment screw A slightly while monitoring RF waveform level in the oscilloscope and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw B slightly and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw A slightly again and set the level to the maximum. (Adjustments should be performed in the order of A, B, A, and please make sure each adjustment is completed as the screws turned to the right.) In case of method 2: Turn the skew adjustment screw A slightly while monitoring RF level in OSD and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw B slightly and set the level to the maximum. At the middle periphery of pickup, turn the skew adjustment screw A slightly again and set the level to the maximum. (Adjustments should be performed in the order of A, B, A, and please make sure each adjustment is completed as the screws turned to the right.)
A
B
B B A
C
A
[Criterion for Skew Adjustment OK] (DVD) Search inner periphery (ID: 40000) and outer periphery (ID: 200000), and respective error rate should be less than 1.000E - 3. If this is not satisfied, start over from step 9. (Disc used: GGV1025) (CD) Conduct a search after moving to the home position by CRG HOME, the error rate should be less than 2.500E - 3. If this is not satisfied, start over from step 9. (Disc used: TCD-782)
D
* If the error rate does not fall within the abovementioned range by method 2, start over by method 1. 10. In FE Test Mode screen, after confirming the disc is stopped by Power OFF, eject the disc by Disc Eject.
E
11. Apply adhesive agent for fixing the skew, and lock the screws. Refer to the next section for the part to be adhered.
F
AVH-P5000DVD/XN/UC
5 6
7
8
77
|
|
 |
> |
|