Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
 ;
the manual is in good quality and it's in pdf. manual was send in less then 24h.
regards
mike
 ;
I would not plug this machine in without finding a manual like this. In addition to setup and normal operating instructions, it has troubleshooting flowcharts, diagrammed mechanical adjustments, and schematics to beat the band. The tech I hand it to would be thrilled to find solder side PCB diagrams with component outlines superimposed, pinouts for every IC chip, and line drawings of transistors, with labeled legs.
As for printing quality, this may be a copy of a copy, but even the finest print when enlarged is very legible. There is a bit of grayed print over a few pages, as if a wet page were placed over it, but the print is still very legible. If you could borrow an original manual and get it printed and bound for 4 to 6 times the cost, you could get better quality. In that case you wouldn't be here. For price, utility, and availability I am rating this manual highly.
 ;
I received the Manual in a timely manner and it was exactly what I needed.
This is a perfect copy of the Service Manual, The quality is great. I am very
happy. Thank you
 ;
exactly as they say. Within 24 hours the link to the pages and offcourse it was the right service manual. Super and thanks
C- N21310 C- N21103 AV-N21203
ADJUSTMENT OF PURITY / CONVERGENCE
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer.
W EDGE DEF LECT ION YOKE
P
2. Loosen the retainer screw of the deflec tion yoke.
3. Remove the wedges.
CR T
4. Input a green raster signal from the signal generator, and turn the screen to green raster.
46
5. Move the deflection yoke backward.
P/C MAGNET S
6. Bring the long lug of the purity magnets on the short lug and position them horizontally. (Fig.2)
% P/C MAGNETS P : PURITY MAGNET 4 : 4 POLES (convergence magnets) 6 : 6 POLES (convergence magnets) Fig.1
7. Adjust the gap between two lugs so that the GREEN RASTER will come into the c enter of the screen. (Fig.3)
8. Move the deflection yoke forward, and fix the pos ition of the deflection yoke so that the whole screen will bec ome green.
9. Ins ert the wedge to the top side of the deflection yoke so that it will not move. 10. Input a cross hatch signal.
Long lug
PURIT Y MAGNET S
11. Verify that the screen is horizontal.
Short lug
12. Input red and blue raster signals, and make sure that purity is properly adjusted.
Bring the long lug over the short lug and position them horizontally.
Fig.2
(F RONT VIEW )
GREEN RASTER
��
CEN TER
Fig.3
No. 51991
23
|
|
 |
> |
|