Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Impressively thorough. Even the simple operators manual helped me "fix" one of the 2 CD players in the unit. This unit reads CD's from the top so they should be installed in the magazines "upside down" from typical CD players. The CD player service manual helped me unjam a stuck carriage because somebody transported the box laying down loaded with CD's. A little lens cleaning & the player now works well! Thanks for you help at a great price! Joe
 ;
I was skeptical at first but later found the manual to be good quality for the price. It took a couple hours to receive the email with the download link, well worth the wait. Thanks.
 ;
very helpful, I could not have cleaned motherboard and replaced the main fan without it
 ;
Good manual, schematics nice and clear with good quality scanning. Woul dhave been nice to have immediate access after purchasing though.
 ;
I was very glad recieving the service manal from You. Manuals were delivered promptly and were correct as advertised. A complete and very usefull service manual with all details. Thank you!
AVX-7000
- Discharging operations
1. When the OPEN key or the ACC is turned �ON�(or detach grille installing ), (2 sec. after) the position motor will be activated under the high speed mode.
2. When the longitudinal position sensing switch (PUSH SW)/(LIFT SW) turns H - L, the position motor will be stopped and, at the same time, the angle motor will be activated at high speed.
3. When the electric potential of the angle encoder reaches 90° (Reference 0° potential + 3.047V), the angle motor will be stopped. (Braking mode) However, if the preceding angle is being memorized, the angle motor will keep running until the memorized angle can be obtained.
90° potential or the memorized position
- Storage operation
1. When the CLOSE key is operated (or 6 sec. after turning �OFF� the ACC while the automatic openclose setting is being turned �ON�), the angle motor will be activated at low speed.
2. At 750ms after the angle 0° potential has been reached, the angle motor will be stopped and the position motor will be activated at high speed. The system will go into stopping movement at the point where the PULL SW is turned �ON� by detection or when the error time is over.