A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
 ;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
 ;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
 ;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
Adjustments
1. TAPE SECTION
Output Level Measurement Point R-CH
Output Level
Input Point Scope 47 kohm VTVM
Input Level Measurement Point L-CH 47 kohm
Test Tape be used
Tape MTT-111N MTT-114N MTT-5511 Contents 3 KHz 10 KHz Blank Use Tape Speed Adjustment Head Azimuth Adjustment Record Frequency Property
1. 2. 3. 4. 5. 1. 2. 3.
HEAD ADJUSTMENT (AZIMUTH) 10KHz test tape(example: MTT-114N) must be used for this adjustment. Connect to VTVM or oscilloscope to the headphone jack or speaker terminal. Press the play button. Adjust the azimuth by using a screw driver to maintain the max. L&R output voltage. Adjust tape A(1), tape B(2) respectively, Please secure the azimuth position by using locking paint. RECORDING BIAS OSCILLATOR FREQUENCY ADJUSTMENT Connect the frequency counter to TP603, GND. Press the REC button. Adjust L603 to obtain 80 KHz±100Hz
Step Item TAPE ALIGNMENT CHART Reference Value Test Tape Adjust Point 3,015~3,025Hz Normal 1 Tape Speed Adjustment High 2 3 Azimuth Adjustment Recording Bias Oscillator Frequency Adjustment 3,000~3,010Hz MTT-111N RV601 MTT-111N RV601 Test Point Line Out L/R Channel Line Out L/R Channel Shorted TP601, TP602 Line Out L/R Channel TP603,GND Adjust with frequency counter connected. Note Confirm Wow & Flutter is within 0.35% Confirm Tape Speed of end position after adjustment at tape start position Confirm High speed after normal speed adjustment FIG. FIG.1 FIG.1
5,820~6,180Hz Maximum Level Phase:Within90° 80 KHz±0.5
MTT-111N MTT-114N MTT-5511
-----Head Screw L603
FIG.1 FIG.2,3,4 FIG.1
Test Tape : MTT-111N(3kHz) MTT-5511(Blank) Set
Frequency Counter
Adjust with Frequency Counter Connected
Output Level Measurement Point
Forward Side
Reverse Side
FIG. 1 : Tape Speed & Record Bias Oscillator Frequency Adjust Circuit
L-CH Peak within 1 dB R-CH Peak within 1 dB
FIG. 2 : Tape Azimuth Adjust Location (Record/Playback Head)
Test Tape MTT-114N (10kHz) L-CH Oscilloscope
Set
V
H
Screw Angle
Output Level Measurement Point Screen Pattern
L-CH Peak
R-CH Peak
Screw Angle
In Phase 45 Good
90
135
180
Wrong
FIG. 3 : Tape Azimuth Adjust Head Screw & Waveform
-4-