Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very good conversation, Pretty fast Service, wood do it again,
Have paid by Paypal, so i got the Service Manual online after 15 Min.
Very helpfully.
Greeting from Germany,
Hans
 ;
Good-quality scans. Detailed description. I hope I can repair the machine.
 ;
High-quality scanning. Detailed description. Recommend for all technician. A+++
 ;
This is a good quality scan of the original Service Manual from Nordmende, Germany. Contains the circuit diagram, PCB layout, adjust/tune instructions as well. It is NOT in English but in GERMAN language! That was quite right for my german friend from the lower east side in Berlin.
 ;
Received via e-mail this PDF manual is worth the money. This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand. I have later seen the original manual and it was printed in colour, but this particular manual is black & white but scan resolution is high end quality! All drawings and pictures are presented in great detail. So, nearly perfect score in my opinion.
If you own the turntable you also should own the manual!
BE-3110
4.2 Adjusting the Clamp Voltage
1. Connect the digital voltmeter to TP1 of the RF ASSY as shown in Connection Diagram 1. 2. Adjust control VR9 (RV9) of the RF ASSY so that the voltage value on the digital voltmeter becomes within DC+2.7 to 2.9V.
Video SG
Video in TP1
BE-3110
Digital voltmeter
Fig. 4-2 Connection Diagram 1
4.3 Adjusting the Video Output
1. Connect the devices as shown by the dotted in Connection Diagram 2. 2. Set the devices as follows. ¶ Oscilloscope 0.1 V/div 5 µs/div H-SYNC TRG. ¶ Video SG All white signal (1 Vp-p/75�) 3. Adjust the oscilloscope using the VARIABLE level knob, etc. so that the p-p value of the signal is at the 6th mark on the oscilloscope screen. (Refer to the video adjustment waveform diagram in Fig. 4-4.) 4. Connect the devices as shown by the solid line in Connection Diagram 2. 5. Adjust control VR8 (RV8) of the RF ASSY so that the p-p value (within 0.97 to 1.03 Vp-p) set in step 3 is obtained.
Video SG
Video in
BE-3110
Video out
Oscilloscope
All white signal (1 Vp-p/75�)
Terminated at 75�
Fig. 4-3 Connection Diagram 2
1 Vp-p/75�
V: 5µs/div
Fig. 4-4 Video Adjustment Waveform Diagram
22
|
|
 |
> |
|