Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I searched EVERYWHERE looking for the manual/s on this "extinct" amp. Owner-Manuals.com made it available and for nearly nothing. Thanx to them, I can decipher the unknown cables and sort them out. Thanx, Owner-Manuals.com!!
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
 ;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
 ;
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
 ;
Very good manual, at a very good price. Received in a timely manner
BE-4130
6. ADJUSTMENT
Perform this adjustment more than 30 minutes after the power is turned on.
7 Equipment used
� � � � � � Spectrum analyzer Oscilloscope Digital voltmeter Video SG Variable resistance attenuator Audio analyzer
BE-4130
DPS Assy
+5V (D) 1 D.GND 6
� FM linear detector � C.W.Signal Generator
Digital Voltmeter
VR1
6.1 DC5V Adjustment
1. Connect the digital voltmeter to CN1004 pin 1 [+5V (D)] and pin 6 [GND (D)] of the DPS ASSY (Connection Diagram 1). +0.02 2. Adjust VR1 of the POWER unit, set to 5.00V - 0.01V
CN1004
POWER Unit
Connection Diagram 1
6.2 Adjustment of DPS ASSY (Video SCR ASSY)
� If deviation of the time axis occurs on the oscilloscope screen, or to move the screen to have a better view, perform fine adjustment using a delay. However do not change the ranges of the vertical and horizontal axes. � When reading the waveform on the oscilloscope screen, read the center of the waveform noise. � If the signal waveform on the oscilloscope is difficult to read, adjust the luminance.
DPS ASSY
VIDEO IN CN3001 (J1001)
VR1004 (RV1004) VIDEO OUT CN3002 (J1002) VR1003 (RV1003) IC1021 IC1020
6.2.1 Adjustment of video output pedestal potential
1. Connect the equipment as shown by the dotted lines in Connection Diagram 2. 2. Set the equipment as shown below. a. Oscilloscope 0.1V/div (DC mode) 5µs/div H-SYNC TRG. b. Video SG Staircase signal (1 Vp-p/75�) 3. Set the oscilloscope to the GND mode, and adjust the oscilloscope so that the luminance line is at the center of the oscilloscope. 4. Connect the equipment to the CN3002 (J1002) of the DPS ASSY using a tool as shown by the lines in Connection Diagram 2. 5. Set the unit to the STANDBY mode. The other functions can be set as desired. 6. Set the oscilloscope to the DC mode, and adjust VR1004 (RV1004) in the DPS ASSY so that the pedestal potential of the video waveform satisfies the GND potential set at step 3 (within 0±0.02V).
VIDEO SG
FL1002 IC1016
VR1001 (RV1001) CN1007
Fig.1 Adjustment Locations
BE-4130 Video in DPS ASSY CN3001 (VIDEO SCR ASSY) (J1001) VR1004 (RV1004)
Video out CN3002 (J1002)
OSILLOSCOPE
Staircase signal 1Vp-p/75�
Terminated at 75�
Connection Diagram 2
33
|
|
 |
> |
|