Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
got exactly what i ordered in a very timely manner. will use again for other manuals
 ;
I'm happy. Good quality. Very helped me with my work..............................
 ;
This is the second Manual I have ordered from owner-manuals, I give it five stars because it is exactly what I expected given the age of the equipment. So the contents look a bit aged and the pictures a bit grainy, it fulfills my needs and I am glad I can still get hold of them.
 ;
thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
 ;
I do not have very much to say.
The price is quite covenient, delivery was better as promised (about 12 ours, against the specified 24 hours if I remember well), and the quality of the PDF is more than acceptable.
The Service Manual of Sansui R30 itself is also satisfactory: good graphic for schematics and layouts, simple and well structured.
Giovanni Bianchi
2-3-3. 3.58 f0 Adjustment
Note 1: ON/OFF of ACC should be performed with BKM127W menu of MAINTENANCE menu. Note 2: The following adjustment menu is below the BKM-127W menu of the MAINTENANCE menu. F0 1. Turn OFF ACC. 2. Input the NTSC color bar signal. 3. Connect TP322 and TP321 (5V) of the BW board using a jumper wire. 4. Connect the oscilloscope to TP421 of the BW board. 5. Adjust the F0 data so that the waveform stops or moves slowly. 6. Turn ON ACC. 7. Disconnect the jumper wire.
2-3-4. Phase Adjustment
Note 1: ON/OFF of ACC should be performed with BKM127W menu of MAINTENANCE menu. Note 2: The following adjustment menus are below the BKM-127W menu of the MAINTENANCE menu. SUB PHASE ACC PHASE R�Y PHASE 1. Input the NTSC color bar signal whose R�Y signal has been turned off. 2. Turn OFF ACC. 3. Connect the oscilloscope to TP421 of the BW board. 4. Adjust the SUB PHASE data so that the TP421 waveform becomes flat. 5. Turn ON ACC. 6. Adjust the ACC PHASE data so that the TP421 waveform becomes flat. TP421
Below 10mV
Fig. 2-5. Fig. 2-4.
7. Input the NTSC color bar signal whose R�Y signal has been turned off. 8. Connect the oscilloscope to TP471 of the BW board. 9. Adjust the R�Y PHASE data so that the TP471 waveform becomes flat. TP471
H Period Below 10mV
Fig. 2-6.
2-4
BKM-120D/127W/129X/142HD
|
|
 |
> |
|