the big video recorder format s-vhs many features delicate in loading system of the cassette. Such machines are no longer manufactured, it would be too expensive.
 ;
THIS MANUAL IS VERY GOOD AND VERY CLEAR
PLEASE NOTE IT DOES NOT CONTAIN THE SETUP INFORMATION TO ALIGHN THE GEARS IN THE CD MECH IT DOES SHOW ALL THE PARTS AND THEIR LOCATIONS .
 ;
Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
 ;
High quality scan of original Service Manual. Everything´s fine!
 ;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
2-3-3. 3.58 f0 Adjustment
Note 1: ON/OFF of ACC should be performed with BKM127W menu of MAINTENANCE menu. Note 2: The following adjustment menu is below the BKM-127W menu of the MAINTENANCE menu. F0 1. Turn OFF ACC. 2. Input the NTSC color bar signal. 3. Connect TP322 and TP321 (5V) of the BW board using a jumper wire. 4. Connect the oscilloscope to TP421 of the BW board. 5. Adjust the F0 data so that the waveform stops or moves slowly. 6. Turn ON ACC. 7. Disconnect the jumper wire.
2-3-4. Phase Adjustment
Note 1: ON/OFF of ACC should be performed with BKM127W menu of MAINTENANCE menu. Note 2: The following adjustment menus are below the BKM-127W menu of the MAINTENANCE menu. SUB PHASE ACC PHASE R�Y PHASE 1. Input the NTSC color bar signal whose R�Y signal has been turned off. 2. Turn OFF ACC. 3. Connect the oscilloscope to TP421 of the BW board. 4. Adjust the SUB PHASE data so that the TP421 waveform becomes flat. 5. Turn ON ACC. 6. Adjust the ACC PHASE data so that the TP421 waveform becomes flat. TP421
Below 10mV
Fig. 2-5. Fig. 2-4.
7. Input the NTSC color bar signal whose R�Y signal has been turned off. 8. Connect the oscilloscope to TP471 of the BW board. 9. Adjust the R�Y PHASE data so that the TP471 waveform becomes flat. TP471
H Period Below 10mV
Fig. 2-6.