MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
 ;
The service was great and the document was also great. Highly recommend!!!!
If anyone has a users manual... Please email me. need one. $ [email protected]
 ;
I needed a service manual as the display on my oscilloscope was very dim. I thought I'd give owner-manuals.com a try, as they advertised a huge number of manuals. Sure enough they had one listed. I bought it hoping it would be useful... actually, I bought it hoping it would be readable! I've had manuals from online sources in the past, and been very disappointed. Not this time! An excellent manual, complete, and very readable. Using it I fixed my 'scope, and as such the manual was an investment that paid off manyfold. Do I have any complaints? One very minor one - The circuit diagrams could have been scanned at a higher resolution, as some of the details were a little difficult to make out - not impossible, just not as easy as my old eyes would like! Overall, I'm very satisfied with my manual, and I will certainly be using this company again. Well done.
http://getMANUAL.com
4-5. DA-136 Board Adjustment
4-5-2. D/A Video Level Adjustment
m Check the following setup menus before starting adjustment. . Check the NTSC/PAL setup. (Refer to menu No. 010 of Section 1-9-2 of the MAV-555 Installation Manual.) . Check the network setup. (Refer to menu No. 220 of Section 1-9-6 of the MAV-555 Installation Manual.) Connection
MAV-555 + BKMA-512
Setting 1. Open �782-INT VD SG R1� of the setup menu. n For details on how to use the setup menu, refer to the Operation Manual. 2. Press the VIDEO/MENU knob once.
782-INT VD SG R1
off
3. Turn the VIDEO/MENU knob and select �CB100�
VIDEO OUT* P1-A or P2-A ETHER Ethernet
(100% color-bar signal).
782-INT VD SG R1
CB100
4. Press the SET button. 5. Set �703-OUT SETUP P1� or �704-OUT SETUP P2� to �off� on the setup menu in accordance with the port that the BKMA-512 is connected to. (Refer to Section
Waveform monitor or an oscilloscope
PC
1-9-5 of the MAV-555 Installation Manual.) n The setting is not required in case of the 625-mode (PAL). 6. Turn off the main power and back on. Restart the MAV-555. n To restart the MAV-555 quickly, execute �027-FAST REBOOT� of the setup menu. 7. Press the R1 button on the PORT SELECT block of the meter panel. (Set so that the internal SG is output to the R1 port.) 8. Press the COMPOSITE button of the VIDEO INPUT SELECT block of the meter panel for at least three seconds. (The internal SG starts, and the COMPOSITE button and the SDI button are turned on.) 9. Press either the P1 or the P2 button of the PORT SELECT block of the meter panel in accordance with the port to which the BKMA-512 is connected. 10. Press the CONTROL button of the VIDEO PROCESS block on the meter panel several times, and enter the LOCAL mode. 11. Set all buttons of VIDEO, CHROMA, SETUP, and CHROMA PHASE on the meter panel to �PRESET�.
* : Connect to the VIDEO OUT P1-A or the VIDEO OUT P2-A in accordance with the port to which the BKMA-512 is connected.
MAV-555