Who's Online
There currently are 5950 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
;
5 STARS for FAST DELIVERY, BEST PRICES and QUALITY PRODUCT. Item was exactly as described with superb resolution. Will definitely source all my future requirements from this website. Thanks a lot owner-manual.com!
;
OEM manual provided all schematics, board layouts and component specs necessary to facilitate unit maintenance. All pages were clear and readable.
;
Good condition and quality. Hard to find anywhere in Internet, only on this site.
;
Exactly what I needed to be able to bring the amp back to life... will come back to this site the next time I need schematics.
2-8. R Signal De-matrix Adjustment 2-9. G Signal De-matrix Adjustment
2-8. R Signal De-matrix Adjustment
Measurement equipment Waveform monitor Procedure 1. Check to see that S505 is set to RGB. 2. Supply 100% color bars signal from the signal generator to the SDI IN connector. 3. Set the waveform monitor as follows. MODE : WAVEFORM INPUT : CH3 REF : EXT 4. Adjust 1RV305 so that the level A satisfies the specification. Use 1RV303 in the fine adjustment so that the peak of each level is flat. n Do not set S505 to YUV until �2-9. G Signal Dematrix Adjustment� is completed. Measuring point : R-Y/R connector (BKPF-102CB connector panel) Adjustment point : 1RV303 (F-6)/DAC-30 (for fine adjustment) 1RV305 (H-6)/DAC-30
2-9. G Signal De-matrix Adjustment
n Adjust the G signal after the B signal (section 2-7) and R signal (section 2-8) adjustments are completed. Measurement equipment Waveform monitor Procedure 1. Check to see that S505 is set to RGB. 2. Supply 100% color bars signal from the signal generator to the SDI IN connector. 3. Set the waveform monitor as follows. MODE : WAVEFORM INPUT : CH1 REF : EXT 4. Adjust 1RV404 so that the level A satisfies the specification. 5. Set S505 to YUV. Measuring point : Y/G connector (BKPF-102CB connector panel) Adjustment point : 1RV404 (H-5)/DAC-30
A A
A = 700 ±14 mV p-p A = 700 ±14 mV p-p
BKPF-102CB
2-5 (E)
|
|
|
> |
|