|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Easy to order the manual. Good quality and fast delivery.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
 ;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
Luminance/chroma time delay adjustment (YD_ _) Respectively input PAL,SECAM,NTSC RF signal or PAL AV signal and adjust YD_ _ to make luminance tallied with chroma. For those model with SVM function, on the condition that SVM is set to ON, input split field or crosshatch signal, respectively adjust YD_ _ until SVM�s edge from black to white is in symmetry with that from white to black, give attention to the data that make luminance tallied with chroma. 4.10 High voltage and filament voltage check 4.10.1 Connect high voltage meter between CRT high voltage cap and GND, use effective and precise voltameter to measure filament voltage. 4.10.2 Receive D35 signal, set picture mode to �DYNAMIC�. Measure the high voltage and filament voltage and the reading should be: for 29� super flat CRT, the high voltage is 29 kV 0.5 kV, for 29� pure flat CRT, the high voltage is 30 kV 0.5 kV, filament voltage 6.3 0.3 Vrms. 4.11 X-ray protection check 4.11.1 Receive normal picture. 4.11.2 Press S301 switch, horizontal scan should stop vibration and turn off. 4.11.3 Turn off the power switch and wait about 30 seconds, turn on the set again, it should restore to normal. 4.12 Beam current check Receive D35 signal, set picture mode to �DYNAMIC�, measure R313 two terminals, for 29� super flat it should be 1.6 V, for 29� pure flat it should be 1.7V. 4.13 AV function check According to Instruction manual, connect the AV equipment to the AV terminals which need to be check, the following is required: VIDEO IN: 1 Vp-p 75 , AUDIO IN: -8 dBm 3 dBm 47 k . 4.14 Out-factory status setting Contrast: Brightness: Colour: Sharpness: Treble: Bass: Balance: 45 28 40 35 31 31 0 Comb filter: Blue back: Black stretch: SVM: AVL: Surround: ON ON ON ON OFF OFF
4.9
The following appendix is factory menu and data.
5
|
|
 |
> |
|