Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great Manual. This manual is available no where else. It was exactly what I was looking for.
 ;
The TEAC A-1500's Service Manual was instrumental in reviving this classic reel-to-reel. Not only does it have the schematics, exploded parts diagram and parts list, it also provided mechanical adjustment information that approximate factory default settings.
 ;
This service manual was determinant to enable to fix my Alpine Amplifier. I am pleased with my purchase. For a 5 star rating I would like to see a higher resolution scan of the printed circuit board lay-out because the gray scale grafics was dificult to see. Also some schematic diagrams were scanned at a slight angle. Never the less, it had all information I needed to troubleshoot and service my equipment.
 ;
Complete manual, the good quality of reproduction allows enlarged print-out of the schematic diagram in the size it probably had in the original print edition and which is necessary for practical use.
 ;
The service manual was complete and the components on the drawings very good visible.
[Dynamic Convergence Adjustment] 1. Minimize the vertical misconvergence in the left-most end of the center of a screen and in the right-most end of the center of a screen by adjusting the DY correction reactor XCV as shown in Fig. 1-15. 2. Minimize the vertical misconvergence in the top of a screen and in the bottom of a screen by adjusting the DY correction reactor YCH as shown in Fig. 1-15. 3. Minimize the vertical misconvergence in the top of a screen and in the bottom of a screen by adjusting the DY correction reactor TLV as shown in Fig. 1-15. 4. Minimize the vertical misconvergence in the left-most end of the center of a screen and in the right-most end of the center of a screen by adjusting the DY correction reactor TLH as shown in Fig. 1-15.
XCV YCH B B G R B R B R G R
[G2 Adjustment] 1. Connect the 480/60i entire black signal to the ANALOG Y/G input connector. 2. Connect an oscilloscope probe one after another to the C board R-cathode (TP701), G-cathode (TP702) then B-cathode (TP703) to measure the DC voltage at their respective pedestal portion. 3. Connect an oscilloscope to the cathode whose DC voltage of the respective pedestal portion has the highest DC voltage. 4. Adjust RV702 on the C board so that the DC voltage of the respective pedestal portion is 125 ± 3 V.
Pedestal
125±3(VDC)
TLV R G B
TLH
0(VDC)
Fig. 1-16
B G R R GB B GR
Fig. 1-15
BVM-D14H1U/D14H5U/D14H1E/D14H5E/D14H1A/D14H5A
3-11
|
|
 |
> |
|