|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Fully functional usable service manual. Considering the age of the manual and device quality was better than expected
 ;
Thank you very much, I've been very happy to find this manual on "Owner Manual". It's a perfect copy and it has been really useful for my work!
 ;
It took about 24-hours after my payment before I was able to get to the download. Apparently, payment processing is not 100% automated. That is no big deal, just be aware of that going in.
After I got to it, it was in good shape, easy to read, etc. Not some cheap FAX copy looking thing.
Also, this site was the cheapest I found. Another Plus!
 ;
Good price, very legible manual, exactly what I needed -- but had to wait a day to actually get the download of the manual. Would have preferred to download it immediately after payment rather than waiting for someone to "process" my order. I was surprised that I had to wait that long.
 ;
As the only source for this manual it rather rank quite high since it is well scanned and perfectly readable.
CP-X260(CC9XM2)
6-11 Related Messages
When the unit�s power is on, messages such as those shown below may be displayed. When any such message is displayed on the screen, please respond as described below. Although these messages will be automatically disappeared around several minutes, it will be reappeared every time the power is turned on.
Message NO INPUT IS DETECTED *** Description There is no input signal. Please con�rm the signal input connection, and the status of the signal source.
SYNC IS OUT OF RANGE The horizontal or vertical frequency of the inputted signal is outside of the *** response parameters of this unit. fH *****kHz fV *****Hz Please con�rm the specs for this unit or the signal source specs. The internal portion temperature is rising. Please turn the power OFF, and allow the unit to cool down at least 20 minutes. After having con�rmed the following items, please turn the power ON again. � Is there blockage of the air passage aperture? � Is the air �lter dirty? � Does the peripheral temperature exceed 35°C? If the same indication is displayed after the remedy, please set FAN SPEED of the SERVICE item in the OPTION menu to HIGH. A note of precaution when cleaning the air �lter. Please immediately turn the power OFF, and clean or change the air filter by referring to the �Air Filter� section of this manual. After you have cleaned or changed the air �lter, please be sure to reset the �lter timer.
CHECK THE AIR FLOW
REMINDER ***HRS PASSED AFTER THE LAST FILTER CHECK. FILTER MAINTENANCE IS ESSENTIAL TO REMOVE WARNING MESSAGE, RESET FILTER TIMER. SEE MANUAL FURTHER INFO.
28
|
|
 |
> |
|