Nice to have the service manual for the Sony DCR-TRV345E now. The document is of excellent quality.
 ;
MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
CP-X260(CC9XM2)
6-11 Related Messages
When the unit�s power is on, messages such as those shown below may be displayed. When any such message is displayed on the screen, please respond as described below. Although these messages will be automatically disappeared around several minutes, it will be reappeared every time the power is turned on.
Message NO INPUT IS DETECTED *** Description There is no input signal. Please con�rm the signal input connection, and the status of the signal source.
SYNC IS OUT OF RANGE The horizontal or vertical frequency of the inputted signal is outside of the *** response parameters of this unit. fH *****kHz fV *****Hz Please con�rm the specs for this unit or the signal source specs. The internal portion temperature is rising. Please turn the power OFF, and allow the unit to cool down at least 20 minutes. After having con�rmed the following items, please turn the power ON again. � Is there blockage of the air passage aperture? � Is the air �lter dirty? � Does the peripheral temperature exceed 35°C? If the same indication is displayed after the remedy, please set FAN SPEED of the SERVICE item in the OPTION menu to HIGH. A note of precaution when cleaning the air �lter. Please immediately turn the power OFF, and clean or change the air filter by referring to the �Air Filter� section of this manual. After you have cleaned or changed the air �lter, please be sure to reset the �lter timer.
CHECK THE AIR FLOW
REMINDER ***HRS PASSED AFTER THE LAST FILTER CHECK. FILTER MAINTENANCE IS ESSENTIAL TO REMOVE WARNING MESSAGE, RESET FILTER TIMER. SEE MANUAL FURTHER INFO.
28
|
|
 |
> |
|