Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
I PURHASED THIS PRODUCT BECAUSE I WAS HAVING PROBLEMS WITH MY CDR20 HARMAN KARDON RECORDER. WHICH I PURCHASED NEW 12 YEARS AGO. AFTER REVIEWING THE MANUAL, I WAS ABLE TO ADJUST THE TENSIONER IN THE SYSTEM. WORKS LIKE A CHAMP!.
SAVED ME AT LEAST 100.00 WHICH WAS WHAT A SERVICE REPAIR STATION WANTED. GREAT MANUAL EASY TO READ. SPECIALLY AFTER I PRINTED THE PAGES WHICH DEALT WITH MY RECORDER. THANKS A LOT!!!!!!!!
 ;
You can fully trust on this one!
All the schematics are very crear an in one piece per page
 ;
I have never bought a service manual which is as competely readable as this althogh it was a scanned pdf. Thank you for this succesful manual also cheaper than other sites.
 ;
Thanks for a very good and readable servicemanual. Just what I needed as a "dinosaur technician". I really recommmend this site and will come back.
Åsbjörn
 ;
The manual I purchased was just what I needed. I was glad to find a site where I can find so many manuals on a wide variety of products.
CD-3260M/3280M/DPF-J7020
ADJUSTMENT
No. ITEM INPUT SETTING OUTPUT SETTING PLAYER SETTING ALIGNMENT POINT ALIGN FOR FIG. 1. With pressing the REPEAT KEY, turn the power on to enter the test mode. 2. Set the Test disc to Disc NO. 1. 3. Close the door. Test disc Type4 /KTD-02 Connect an oscilloPress the PLAY scope as follows. /PAUSE key . CH1:RF(* X25, CN2-1 Confirm that the X32, CN2-1) display is "05". *CD-3280M
1
FOCUS ERROR BIAS
FE BIAS VR1
Optimum eye pattern
(d)
Note: Type 4 disc :SONY YEDS-18 Test Disc or equivalent. LPF : Around 47k� + 390 pF or so. FIG. (d)
RF signal
� �
RF signal in test mode (PLAY). Perform the tangential and focusing offset are focused into one point on the display. The crossing points above and below the center shall also be looked clearly. (FE BIAS)