RF PLL Free-run Frequency Check Procedure : 1. Connect frequency counter to test point (PLCK) with lead wire.
frequency counter BD board TP (PLCK)
Adjustment Location : [ BD BOARD ] � Conductor Side �
1
20
(FE) (FEI) (TE)
IC103
(RF)
11
2. Turned Power switch on. 3. Put the disc (YEDS-18) in to play the number five track. Confirm that reading on frequency counter is 4.3218MHz.
(PLCK)
10
(VC)
IC101
[ MAIN BOARD ] � Conductor Side �
41 40 64 65 80 1
IC401
25 24
TP2 (ADJ)
�9�
|