Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was very glad recieving the service manal from You. Additionaly very fast. Extremaly nice servicing. Thanks very mach! Now my GX-220 working better, than it was made. Alexander from Moscow, Russia/
 ;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
 ;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
 ;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
SECTION 4 ELECTRICAL BLOCK CHECKING
Note :
1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M impedance. 4. Clean the object lens using an applicator with neutral detergent when the signal level is low than specified value with the following checks. S Curve Check
oscilloscope BD board TP (FE) TP (VC)
Note: Clear RF signal waveform means that the shape � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns level : 1.2 +0.25 Vp-p
�0.20
E-F Balance Check
oscilloscope BD board TP (TE) TP (VC)
Procedure : 1. Connect oscilloscope to test point TP (FE) on BD board. 2. Connect between test point TP (FEI) and TP (VC) by lead wire. 3. Turn Power switch on. 4. Put disc (YEDS-18) in and turn Power switch on again and actuate the focus search. (actuate the focus search when disc table is moving in and out.) 5. Check if the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 3±1 Vpp.
S-curve waveform symmetry
Procedure : 1. Connect test point TP1 (ADJ) to ground with a lead wire on MAIN board. 2. Connect oscilloscpe to test point TP (TE) on BD board. 3. Turned Power switch on. 4. Put disc (YEDS-18) in to play the number five track. 5. Press the �3� button. (The tracking servo and the sledding servo are turned OFF.) 6. Check the level B of the oscilliscope's waveform and the A (DC voltage) of the center of the Traverse waveform. Confirm the following : A/B x 100 = less than ± 22%
A within 3 ± 1 Vp-p B
Traverse waveform Center of the waveform B 0V A (DC voltage)
6. After check, remove the lead wire connected in step 2. Note : � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform. RF Level Check
level : 1.3 ± 0.6 Vp-p
7. Press the �8� button. (The tracking servo and sledding servo are turned ON.) Confirm the C (DC voltage) is almost equal to the A (DC voltage) is step 6.
oscilloscope Traverse waveform
BD board TP (RF) TP (VC)
Procedure : 1. 2. 3. 4. Connect oscilloscope to test point TP (RF) on BD board. Turned Power switch on. Put disc (YEDS-18) in to play the number five track. Confirm that oscilloscope waveform is clear and check if RF signal level is correct or not.
0V Tracking servo Sledding servo OFF Tracking servo Sledding servo ON
C (DC voltage)
8. Disconnect the lead wire of TP (ADJ) connected in step 1.
�9�
|
|
 |
> |
|