I work at an authorized service center and I can tell if a manual is as it should be. This one is. It may be a scan, but a very good one at that. The interesting part for me was the curcuit diagram which was scanned at high quality, making it as good as the original. I will definitely be back as a customer. I need not say this, but I will: the price was the best. Thank you owner-manuals.com .
 ;
really a very good manual even sometimes the quality is no so good as before still very readible and very very useful!
 ;
FAST very good and clear a great unexpensive job!!! very recomended for all people who are preofessional or hobbists as me!!!!!!
 ;
Thank you very much for this Service Manual, it helped us a lot to repair the M-4318!
...BUT: The parts list is missing and the free parts katalog on web isn't complete, so now we don't know the part numbers of the defect parts :(
We had to build them out of a working machine, and need the numbers to reorder the missing parts now.
 ;
Very good manual with clear electrical diagrams. Thanks owner-manuals.
6-2. ELECTRICAL ADJUSTMENT
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. S-Curve Check
oscilloscope BD board TP (FE1) TP (VC)
Note: A clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.
RF signal waveform
VOLT/DIV : 200mV TIME/DIV : 500ns level : 1.2
+0.25 �0.20
Vp-p
Adjustment Location: BD board E-F Balance Check
oscilloscope BD board TP (TE) TP (VC)
Procedure : 1. Chuck the disc (YEDS-18) beforehand, and disconnect the power cord from the outlet. 2. Connect oscilloscope to test point TP (FE1) on BD board. 3. Connect test point TP1 (ADJ) on MAIN board to ground with lead wire. 4. The ADJ mode is set when the power cord is inserted into the outlet and power is supplied. 5. The fifth track is played automatically. 6. Press the CHECK button. 7. Check the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 3±1 Vp-p.
S-curve waveform
symmetry
Procedure : 1. Chuck the disc (YEDS-18) beforehand, and disconnect the power cord from the outlet. 2. Connect oscilloscpe to test point TP (TE) on BD board. 3. Connect test point TP1 (ADJ) on MAIN board to ground with lead wire. 4. The ADJ mode is set when the power cord is inserted into the outlet and power is supplied. 5. The fifth track is played automatically. 6. Press the GROUP 3 button. (The tracking servo and the sledding servo are turned OFF.) 7. Check the level B of the oscilliscope's waveform and the A (DC voltage) of the center of the Traverse waveform. Confirm the following : A/B x 100 = less than ± 22%
A Within 3 ± 1 Vp-p B
Traverse waveform
Center of the waveform B
8. Pressing the 1/u button stops the output of the waveform (s curve). 9. After check, remove the lead wire connected in step 3. Note : � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform. Adjustment Location: BD board
0V
A (DC voltage)
level : 1.3 ± 0.6 mVp-p
8. Press the GROUP 8 button. (The tracking servo and sledding servo are turned ON.) Confirm the C (DC voltage) is almost equal to the A (DC voltage) is step 7.
Traverse waveform
RF Level Check
oscilloscope BD board TP (RF) TP (VC)
0V
C (DC voltage)
Procedure : 1. Connect oscilloscope to test point TP (RF) on BD board. 2. Turn Power switch on. 3. Put disc (YEDS-18) in to play the number five track. 4. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not.
Tracking servo Sledding servo OFF
Tracking servo Sledding servo ON
9. Disconnect the lead wire of TP1 (ADJ) connected in step 2. Adjustment Location: MAIN board