Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
 ;
We received the manual in a timely manner and it was exactly what we were expecting.
 ;
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
 ;
Very good scanning quality. All schematics are very legible. Worth every cent !
 ;
Excellent quality, very quick download turnaround, will definately use again.
DISC IN DETECT SENSOR ADJUSTMENT Be sure to perform this adjustment after sensor adjustment in MECHANICAL ADJUSTMENT. Connection:
MAIN board TP1 T.P GND D.S T.P: Pin 1 D.S: Pin 3 GND: Pin 2 oscilloscope (DC range)
D.S
T.P
Waveform:
Should be at the center
D.S
T.P
5. Rotate the [DISC/CHARACTER] knob in the counterclockwise direction and the disc table starts to rotate in the same direction. Check that the waveform at this time is the same as that in step 4. If larger by a considerable extent, rotate the [DISC/CHARACTER] knob in the clockwise direction and the disc table starts to rotate in the same direction. Repeat from step 4. 6. Rotate RV501 of the MAIN board and adjust so that the H and L portions of the D.S waveform become the same.
1. Connect the oscilloscope to Pins 1, 2, and 3 of TP1 of the MAIN board. 2. Check that no discs are loaded in the unit. 3. With the power ON, while pressing the [GROUP FILE] and [MEGA CTRL] buttons, press the I/1 button. Rotate the [DISC/ CHARCTER] knob, select �Table Rotation� and press the knob. The disc table starts to rotate in the clockwise direction. 4. Loosen the fixing screw, move the mounting board (SENSOR), and secure the mounting board (SENSOR) at the point the H portion of the P.T waveform comes the center of the H portion of the D.S waveform.
D. SENS (OUT) board
D.S Adjust so that these widths become the same.
Adjustment Location: MAIN board
S tight, screw (PTTWH 3 � 6)