This scanned manual is well done in that most all the pages except for one is straight and clear- the way I would do them. One page was upside down but that happens. For the money that is charged on this site you get a pretty good deal. Now with complex repairs, I still prefer to us paper manuals which I have to buy at stereomanuals but the one I got here was much less than the $45 he was charging but this is a larger than normal manual for three different units. I am a picky manual user because I have used original manuals from Sony and Teac.
 ;
Very useful service manual, was exactly what i needed.Good quality,reasonable price.Thank you.
CDR-850
6.5.4 Focus Bias Adjustment
Test Point Adjustment Point Adjustment Value
CN354 - pin 1 (RF) DIGITAL SYNCHRO button, RECORD button and REC MUTE button Adjust until RF jitter is minimal or that the eye pattern of the RF waveform is most open.
[Procedure]
(1) Press the DIGITAL SYNCHRO button in Stop mode. Note: Make sure the unit is in Stop mode. (2) Check that "48" appears on the FL display. (3) Press the AUTO/MANUAL button so that "04 34" appears on the FL display. (4) Press the FINALIZE button for focus-in. (5) Press the PLAY button for CAV-servo spindle kick. (6) Press the PAUSE button to close the tracking servo, then set the unit to Playback mode. (7) Adjust with the RECORD and REC MUTE buttons until the above adjustment value to be reached is obtained. Press the SET button to register the adjustment. Once the adjustment is registered with the SET button, "?" on the FL display will disappear. (8) Press the STOP button to stop the unit.
RF 10 : 1 VC 10:1 probe Jitter Meter or Oscilloscope
Note: Adjustment must be done around mid-radius on a disc.
58
|
|
 |
> |
|