Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
 ;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
 ;
I really like this manual and it's reliable.I found and bought easly.thank you.
CORNER ADJUSTMENT 1. Receive cross hatch pattern and set screen mode to �FULL�. 2. Enter to the service mode and select mode �WIDE�, and select item no. 10 �WIDE 10.P CNR�. 3. Press the LEVEL+ or LEVEL - button to correct the distortion of the vertical line around the corners.
VERTICAL HEIGHT ADJUSTMENT 1. Receive circular pattern and set screen mode to �FULL�. 2. Enter to the service mode and select mode �WIDE�, and select item no. 5 �WIDE 5.P V-S. 3. Press the LEVEL+ or LEVEL - button to adjust the vertical height.
HORIZONTAL ADJUSTMENT HORIZONTAL CENTRING ADJUSTMENT 1. Receive circular pattern and set screen mode to �FULL�. 2. Enter to the service mode and select mode �WIDE�, and select item no. 2 �WIDE 2.P H-P�. 3. Press the LEVEL+ or LEVEL - button to adjust the horizontal centre. HORIZONTAL WIDTH ADJUSTMENT 1. Receive circular pattern and set screen mode to �FULL�. 2. Enter to the service mode and select mode �WIDE�, and select item 6 �WIDE 6.P H-W�. 3. Press the LEVEL+ or LEVEL - button to adjust the horizontal width. OSD POSITIONING ADJUSTMENT 1. Receive circular pattern and set screen mode to �FULL�. 2. Enter to the service mode and select mode �REGULAR�, and select item no. 8 �REGULAR 8 OSD�. The OSD test bar will appear on the top of screen. 3. Press the LEVEL+ or LEVEL - button to adjust proper OSD positioning. ��������������������
HIGH-VOLTAGE CONFIRMATION 1. Receive circular pattern and set screen mode to �FULL�. 2. Set controls to normal. 3. Connect high-voltage meter to the anode of CRT and GND. 4. Confirm that voltage is 29.0±1.0kV at 1.2mA for 25� model. VERTICAL ADJUSTMENT VERTICAL CENTRING ADJUSTMENT 1. Receive circular pattern and set screen mode to �FULL�. 2. Enter to the service mode and select mode �WIDE�, and select item no. 1 �WIDE 1.P V-P�. .3 Press the LEVEL+ or LEVEL - button to adjust the vertical centre.