Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Thank you for your manual It has the basic things to and i use the Oszi for Longer Time.
THX
 ;
Actually, I was looking for this information for 3 years!...now thanks to you, the manual is on my hands and of great help, cause I understand now where I was doing wrong connections and wires...excellent, I'll be back to you if in need, thank you.
 ;
This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
 ;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
 ;
The manual was properly scanned and perfectly readable. The only small problem is that I couldn't use my dear Ctrl + F to find a word I needed.
Scanning PLU maintenance by consolidating the not found PLU file
During registrations, the item that has not existed in the PLU or not found PLU file is stored in the not found PLU file when the item is registered. So, after business hours, you should merge the items in the not found PLU file to the PLU (main) file. To merge the contents of the not found PLU file to the main file, consolidation of the not found PLU is necessary, even if you have only one scanning terminal. Consolidation for not found PLU processing is performed as the figure shown below. (Only �consolidate all terminals� is possible.)
1, 9 Satellite
Not found PLU file
Master
Not found PLU file
4, 7
5
2 3, 6 Consolidation file
Not found PLU maintenance file
1 A consolidation command is started up from the master terminal. The master first locks objected terminals. No report is printed out on the satellite R/J printer. 2 Data of the master's not found PLU file is copied to the consolidation file. 3 Data of the consolidation file is merged in the not found PLU maintenance file. (If the same item exists in the maintenance file, the merger of this item is skipped.) 4 Issue not found PLU report, and reset the not found PLU file if Z consolidation is performed. 5 Data of the satellite's not found PLU file is copied to the master�s consolidation file. 6 Data of the consolidation file is merged in the not found PLU maintenance file. (If the same item exists in the maintenance file, the merger of this item is skipped.) 7 Issue not found PLU report, and reset the not found PLU file if Z consolidation is performed. 8 The same process described in steps 5 ~ 7 is executed for other terminal. 9 After the above consolidation processing completes for all target terminals, satellite's Z lock statuses are released. To merge the items in the not found PLU file, perform the �Not found PLU maintenance� (refer to the �Scanning PLU section.�)
Standalone Z consolidation processing (except for scanning PLU)
In case of your store has one terminal per one store and every terminal are connected via online, you can consolidate the daily total not by executing consolidation but issuing report. (A program is necessary to use this option. Refer to the address code 13 of the general function program.) Standalone Z consolidation processing is performed as the figure shown below.
1 Master Terminal files 2 Consolidation files
1 A Z report issuance command is executed. 2 Data of the terminal files are added to the consolidation file, and the Z report of the files are issued. 3 The files of the terminal are cleared.
2
CE-7000/TK-7000/TK-7500/TK-T500/TK-6000/TK-6500 Dealer's Manual
177
Consolidation
|
|
 |
> |
|