There are currently no product reviews.
 ;
Easy to order the manual. Good quality and fast delivery.
 ;
The Service Manual for Sansui AU-9500 was very helpfull, in complete and in good printable condition.
Thanks.
 ;
Dear Sir,
Document is original service document of sharp. I had a problem with the door contacts. Fuses where blown. With the manual in a few minuts is was clear what the problem was.
Manual was of great help.
With kind regards,
Martie Verhoeven
The Netherlands.
 ;
The scan is clear and well readable with very few weaker spots, usually on black background with white letters, but with enough zoom those spots can be read.
Printout is clear, the manual is complete and has all pages scanned.
I would give 5 stars, except that it is not in color, and the schematic and PCB pages are scanned on multiple pages. The document is locked (except printing) so the pages can not be extracted to compose them together for printing on the large plotter
It is worth the price tag.
 ;
let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
Reinstallation Procedure 1. Remove the Imaging Unit from its aluminum pack. 2. Tilt the Imaging Unit to the left and shake it a small stroke in the tilt direction twice. Then, tilt it to the right and shake it a small stroke in the tilt direction twice. NOTES � Since the Imaging Unit is highly susceptible to light, keep it shielded from light up to the time it is installed. � Carefully unseal the aluminum pack. � If the Imaging Unit is packed in the aluminum package again, seal the package using tape or another means. 3. Remove the protective tapes
4025U024AA
protective tape
C4587U013AA
4. Remove the shipping cushion. CAUTION � Make sure that the protective sheet is rolled up into the Imaging Unit as shown in the <OK>. <OK> <NG> protective sheet
C4587U015AA
protective sheet
NOTE � When installing the Imaging Unit, ensure that the color of the mounting guide of the Imaging Unit is the same as the color of the label at the mounting position on the main unit. 5. Keeping the Imaging Unit in a level position, insert the Imaging Unit into the mounting position all the way until it is stopped. NOTE � Do not allow the Imaging Unit to become tilted while installing them into the Main Unit, as damage to the PC Drum or the LED assembly can result.
4025U028AC
E-24
|
|
 |
> |
|