Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
 ;
muy buen manual completo de buena calidad de impresion preciso y detallado , muy útil para la reparación.
CFD-S26L/S36L SECTION 4 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the rated power supply voltage (9V) unless otherwise noted. Torque Measurement Mode FWD Torque meter CQ-102C Meter reading 2.95 � 6.86 mN � m (30 � 70 g � cm) (0.42 � 0.97 oz � inch) 0.15 � 0.53 mN � m (1.5 � 5.5 g � cm) (0.021 � 0.076 oz � inch) CQ-201B more than 5.88 mN � m (more than 60 g � cm) (more than 0.83 oz � inch) more than 5.88 mN � m (more than 60 g � cm) (more than 0.83 oz � inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
TAPE SECTION 0 dB = 0.775 V
� Standard Output Level Output terminal load impedance output signal level � Test Tape Type WS-48A Signal 3 kHz, 0 dB Used for tape speed adjustment HP OUT 32 � 0.25 V (�10 dB)
Tape Speed Adjustment Procedure: Mode: playback
test tape WS-48A (3 kHz, 0 dB) 32 � set i jack (J321) digital frequency counter
FWD Back Tension
CQ-102C
FF
REW
CQ-201B
Adjust so that the value on the digital frequency counter is 3,000 Hz. Tape Tension Measurement Mode FWD Tension meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz) Specification Value: Digital frequency counter 2,940 to 3,060 Hz Adjust so that the frequency at the beginning and that at the end of tape winding are between 2,970 to 3,030 Hz. Adjustment Location:
Tape speed adjustment control inside motor
12
|
|
 |
> |
|