Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It's a full manual. All the parts are in there. I haven't found the problem yett, but I am working on it; hope I can rebuild the part myself. To make it more secure and unbreakable this time. Because the part has failed several times before and costs a lot to let it be repaired.
Thanks so much for this rich illustrated and parted manual.
 ;
I downloaded the document. The manual was complete, well scanned and everything was legible. I could zoom in see what I needed to know. There's not much more that you can ask.
 ;
It was complete service manual with all needed service informations. Thanks.
 ;
El manual esta muy detallado, los numeros de partes y los esquemas de despiece son correctísimos y muy claros, tanto para los técnicos experimentados como para los novatos.
 ;
Ottima qualità grafica e completo nelle notizie. Costo abbastanza contenuto.
SECTION 3 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. Torque Measurement Mode FWD FWD Back Tension FF REW CQ-201B CQ-201B Torque meter CQ-102C CQ-102C Meter reading 30 � 70 g � cm (0.42 � 0.97 oz � inch) 1.5 � 5.5 g � cm (0.021 � 0.076 oz � inch) more than 60 g � cm (more than 0.83 oz � inch) more than 60 g � cm (more than 0.83 oz � inch)
SECTION 4 ELECTRICAL ADJUSTMENTS
TAPE SECTION 0 dB = 0.775 V
� Standard Output Level Output terminal load impedance output signal level � Test Tape Type WS-48A Signal 3 kHz, 0 dB Used for tape speed adjustment HP OUT 32 � 0.25 V (�10 dB)
Tape Speed Adjustment Procedure: Mode: playback
test tape WS-48A (3 kHz, 0 dB) 32 � set phones jack digital frequency counter
Adjust so that the value on the frequency counter is 3 kHz. Tape Tension Measurement Mode FWD Tension meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz) Specification Value: Digital frequency counter 2,985 to 3,015 Hz Adjust so that the frequency at the beginning and that at the end of tape winding are between 2,955 to 3,045 Hz. Adjustment Location:
Tape speed adjustment control inside motor