I found this manual to be complete in every detail. Besides the schematic it has a complete set of alignment instructions which are easy to understand. It also includes a complete parts list as well as an explanation of how the power supply and safety shutdown circuits operate. Even a schematic of the tuner is included.
 ;
The product was good and just what I needed, however I had moderate difficulty with the down load because the sight would not recognize my pass word. I was finally given a direct link to the manual and that worked.
 ;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
 ;
It is an very good and clear scanned service manual.
very recommended.
CD SECTION
Notes on Check 1. Perform the traverse check in the CD test mode. 2. 3. After check, be sure to exit the test mode. Perform check in the order given. Use the disc (YEDS-18, Parts No. 3-702-101-01) only when so indicated.
E-F Balance Check Adjustment Location : MAIN board (See page 23) This check is to be done when the optical pick-up block is replaced. Check Procedure: 1. Connect the oscilloscope to test point TP (VC) and TP (TE) on MAIN board. 2. Put the set into test mode. 3. Optical pick-up setting to the center by + or = button pushing. 4. Insert disk (YEDS-18) and press ^ button. 5. Check that the oscilloscope traverse waveform is symmetrical, as shown in the figure below. 6. Release test mode after adjustment is completed.
Before Check Put the set into test mode and perform the following checks. Repair if there are any problems. � Sled Motor Check Press + , = keys and confirm that the Optical pick-up moves smoothly from the innermost to outermost circumference and back smoothly and with no catching or abnormal noises. (Cancellation of BTL mute) + : Optical pick-up moves to the outer circumference. = : Optical pick-up moves to the inner circumference. � 1. 2. Focus Search Check Press the CD ^ key. (Focus search operation is performed continuously.) Look at the Optical pick-up objective lens and confirm that it moves up and down smoothly, with no catching or abnormal noises. Press p button. Confirm that focus search operation stops. If it does not, press p button again longer.
A 0V B A=B C = 500mV ± 100mV C
VOLT/DIV : 0.1V TIME/DIV : 1ms
[MAIN BOARD]
3.
How to Enter the Set into Test Mode 1. Turn the AC CORD IN (Adaptor). (LCD 501 indicator blinks the test mode pattern.) 2. Short-circuit between the lands as shown on the control (1) board. How to Exit the Test Mode Turn the POWER OFF.
TP(FE) TP(VC)
TP(TE)
[CONTROL (1) BOARD]
TP(RF)
Osilloscope (DC range) TP(TE) TP(VC)
+ �
Jumper wire Test portion Short : Test mode Open : Normal mode
� 14 �