Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
 ;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
 ;
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
 ;
Very good manual, at a very good price. Received in a timely manner
 ;
Only thу cover has poor quality, internal material has excellent quality - exactly what I needed
Thanks!
Alignment and Adjustments
4-3-3 High Voltage Check
CAUTION: There is no high voltage adjustment on this chassis. The B+ power supply must be set to +130/155 volts. (Full color bar input and normal picture level).
4-3-6 Purity Adjustment
1. Warm up the receiver for at least 20 minutes. 2. Plug in the CRT deflection yoke and tighten the clamp screw. 3. Plug the convergence yoke into the CRT and set in as shown in Fig. 4-1. 4. Input a black and white signal. 5. Fully demagnetize the receive by applying an external degaussing coil. 6. Turn the CONTRAST and BRIGHTNESS controls to maximum. 7. Loosen the clamp screw holding the yoke. Slide the yoke backward or forward to provide vertical green belt. (Fig. 4-2). 8. Tighten the convergence yoke. 9. Slowly move the deflection yoke forward, and adjust for the best overall green screen. 10. Temporarily tighten the deflection yoke. 11. Produce blue and red rasters by adjusting the low-light controls. Check for good purity in each field. 12. Tighten the deflection yoke.
1. Connect a digital voltmeter to the second anode of the picture tube. 2. Turn on the TV. Set the Brightness and Contrast controls to minimum (zero beam current). 3. The high voltage should not exceed 30KV. 4. Adjust the Brightness and contrast controls to both extremes. Ensure that the high voltage does not exceed 30KV under any conditions.
4-3-4 FOCUS Adjustment
1. Input a black and white signal. 2. Adjust the tuning control for the clearest picture. 3. Adjust the FOCUS control for well defined scanning lines in the center area of the screen.
4-3-5 Screen Adjustment
1. Connect CRT socket pin RK to an oscilloscope probe. 2. Input a gray scale pattern. (Use a pattern generator, PM5518) 3. Use the P mode key (on the remote control) for the STANDARD picture. 4. Adjust the Screen VR (on the FBT) so that the voltage (See Fig.4-1.) on the oscilloscope becomes 130 + 2.5V.
130V _ 2.5Vp-p +
GND H-Blanking
Fig. 4-1 4-8 Samsung Electronics
|
|
 |
> |
|