There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
Picture is not displayed (LED is lit)
Is the LED red or green? green Do the Fans rotate?
red
Is the voltage applied to pin ² (PAS) No of the Signal PWB correct? Yes
No
AC/DC Power unit
Yes
With J106 (AC/DC Power unit) disconnected, is the picture displayed?
No
² +5.6V ´ GND
AC/DC Power unit Yes DC Fan No low (0V)
Is the voltage of pin - (J104) on the AC/DC Power unit 5V?
Is Voltage of the pin - (PAS) on the Signal PWB high? high (5V) Signal PWB
Yes Are the voltages of pins ¯, ² (J103) on the AC/DC Power unit correct? Yes ¯ +165V ² + 70V ¬ GND Are the voltages of the DC/DC Power unit correct?
AC/DC Power unit
AC/DC Power unit
No
Is the voltage of pin ³ (J102) on the AC/DC Power unit correct? No Yes ³ +3V ´ GND AC/DC Power unit
No (1.5V)
Panel Module
Yes See page 6 Panel Module DC/DC Power unit
5
|