El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
HCD-EP50 SECTION 4 MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. � Torque Measurement
Mode FWD FWD Back Tension FF Torque Meter CQ-102C Meter Reading 2.95 � 6.86 mN�m (30 � 70 g�cm) (0.42 � 0.97 oz�inch) 0.15 � 5.39 mN�m (1.5 � 5.5 g�cm) (0.021 � 0.076 oz�inch) more than 5.89 mN�m (more than 60 g�cm) (more than 0.83 oz�inch) REW CQ-201B more than 5.89 mN�m (more than 60 g�cm) (more than 0.83 oz�inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
PRECAUTION
1. Setting MEGA BASS switch : OFF
TAPE DECK SECTION
Test tape
Type WS-48B P-4-A100 Signal 3 kHz, 0 dB 10 kHz, �10 dB
0 dB=0.775 V
Used for Tape Speed Adjustment Head Azimuth Adjustment
Tape Speed Adjustment Setting: Function: TAPE
test tape WS-48B (3 kHz, 0 dB) 47 k� set + � MAIN board SPEAKER terminal (CN17)
frequency counter
CQ-102C
CQ-201B
Procedure: 1. Playback WS-48B (tape center) in the FWD state. 2. Adjsut the volume in CAPSTAN/REEL motor so that the frequency counter reading becomes 3,000 Hz. Specified Value: 2,970 to 3,030 Hz 3. Confirm that the frequency at the beginning and that at the end of tape winding are between 2,955 to 3,045 Hz. Adjustment Location:
� Tape Tension Measurement
Mode FWD Tension Meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz)
CAPSTAN/REEL motor
Tape Speed Adjustment
11
|
|
 |
> |
|