It's great to be able to obtain a precious technical information for a real old equipment. The one I got helps me a lot in the area of wiring diagram to repair my antique. PDF gave me clear enough information to find out thr details. Thanks for giving me the oppotunity to be able to access to almost vanished informations.
 ;
Another excellent aquisition. Fine detailed manual. Thanks
 ;
Good quality for the scan, complete, but as usual for Tascam, not so comprehensive !
5. OCP (OVER CURRENT PROTECTION) CIRCUIT
This circuit is designed to protect the circuit from over current due to overload occurred at the rear of 123[V] line 1) CONFIGURATION OF OCP CIRCUIT
2) EXPLANATION OF THE OPERATION There is very little voltage drop at R423 of 123[V] line. In case that the overload occurs at the rear of 123[V] line, the increase of the voltage drop at R423 bring down the base voltage of the Q407 os as to drive the Q407 Because of the overload at the rear of the R423, the voltage of the point decreases. And this makes Q407 turn on so that a voltage is applied to the #31 of l701. In case that OCP operates by the #31 of the l1701, the set is protected by power off (#42 of l1701 LOW).