13. CCD White point Defect Detect Adjustment [Adjustment method] � Double-click on the DscCalDi128.
VAA11801-R.3578.A
� Select the CCD Defect from Test menu of Calibration Soft and click the OK. Refer to FIG-1. � After adjustment, An adjustment value will appear on the screen. Refer to FIG-2.
<FIG-2> CCD Defect
<FIG-1>
CCD Black
14. CCD Black point Defect Detect Adjustment [Note] When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. (Do not enter any light.) [Adjustment method]�� ·Double-click on the DscCalDi128. ·Select the CCD Black from Test menu of Calibration Soft and click the OK. Refer to FIG-1. ·After adjustment, An adjustment value will appear on the screen. Refer to FIG-3.
<FIG-3>
������
����������������� ������������
- A17 ï½¥ E5700 -
|