CPD-2401
4. Display crosshatch pattern with red and blue lines and black field. 5. Adjust H.STAT and V.STAT with 4 pole magnet. Use 4 pole magnet, not "HSTAT" and "VSTAT". 4 Pole Magnet
TLV movement
15. If necessary, repeat steps 3-14 to make the optimum condition for the entire screen. 16. Fix 4-pole magnet, 6-pole magnet and XCV VR with white paint Zero Position NECK Ass'y
6. Display crosshatch pattern with white lines and black field. 7. Adjust HMC and VMC with 6 pole magnet. 6 Pole Magnet
4-5. Vertical and Horizontal Position and Size Specification
a
fH > 60kHz a = 2.0 mm b = 2.0 mm fH < 60kHz 2.4 mm 2.4 mm
8. Display crosshatch pattern with red and blue lines and black field. 9. If necessary, repeat steps 5-8. 10. Change "CONV_OFF_NDX" to "3". 11. Adjust H.TILT with TLH plate. TLH movement
RB BR
A
A 234
B 312
B b
4-6. Focus adjustment Adjust focus (V) and focus (H) for optimum focus.
12. Adjust XCV with XCV VR. XCV movement
Focus (V)
13. Adjust YCH with YCH VR. YCH movement
FBT
Focus (H)