3-5-4. Focus Bias Adjustment
Test Point Adjustment Point Adjustment Value [Procedure] (1) Press the DIGITAL SYNCHRO button in Stop mode. NOTE: Make sure that the unit is in Stop mode. (2) Check that �48� appears on the FL display. (3) Press the AUTO/MANUAL button so that �04_34� appears on the FL display. (4) Press the FINALIZE button for focus-in. (5) Press the PLAY button for CAV-servo spindle kick. (6) Press the PAUSE button to close the tracking servo, then set the unit to Playback mode. (7) Adjust with the RECORD and REC MUTE buttons until the above adjustment value to be reached is obtained. Press the SET button to register the adjustment. Once the adjustment is registered with the SET button, �?� on the FL display will disappear. (8) Press the STOP button to stop the unit.
RF 10 : 1 VC 10:1 probe Jitter Meter or Oscilloscope
CN354 - pin 1 (RF) DIGITAL SYNCHRO, RECORD and REC MUTE buttons Adjust until the RF jitter is minimal or that the eye pattern of the RF waveform is most open.
NOTE: Perform the adjustment in STOP mode. This adjustment is possible with the low-pass filter used in adjustment 5 above attached.