CR-315/315DAB SERVICE PROCEDURE-2
2. Initialize the unit (1) Press and the hold down the STOP button, then press the STANDBY/ON button at power on state. Preset memory and each mode stored in the memory, are initialized and will return to the factory settings.
FL Display
Clear
Standby
(2) Disconnect the AC power cord from a wall outlet. 3. Check version of microprocessor. Main microprocessor (Q709), Servo microprocessor (Q101), Sub microprocessor (Q801). (1) Press and the hold down the DISPLAY button, then press the STANDBY/ON button at power on state.
FL Display <EX.>
S YS : 1. 0 5 Ma i n: 0 6 6 2 8 a
Release version
(2) Press the INPUT button. Main microprocessor version
(3) Press the INPUT button.
C heck S u m : E3 3 8
(4) Press the INPUT button.
Check sum
CR 3 1 5 E U R
(5) Press the INPUT button.
Model & Destination
S e rv : 0 5 8 0 5 a
(6) Press the INPUT button.
Servo microprocessor version
Su b : 0 3 5 0 6 a
(7) Press the STANDBY/ON button.
Sub microprocessor version