Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Very good reproduction (copy) of original manual. Didn't have a parts list, but schematic was completely labeled with parts. Complete instructions on how to adjust mechanical functions of the 8-track deck. Well worth having and at a very reasonable cost.
 ;
It's a full manual. All the parts are in there. I haven't found the problem yett, but I am working on it; hope I can rebuild the part myself. To make it more secure and unbreakable this time. Because the part has failed several times before and costs a lot to let it be repaired.
Thanks so much for this rich illustrated and parted manual.
 ;
I downloaded the document. The manual was complete, well scanned and everything was legible. I could zoom in see what I needed to know. There's not much more that you can ask.
 ;
It was complete service manual with all needed service informations. Thanks.
 ;
El manual esta muy detallado, los numeros de partes y los esquemas de despiece son correctísimos y muy claros, tanto para los técnicos experimentados como para los novatos.
B CD C.B
TP4
1
IC404
TP3
IC401
1
SFR430
A MAIN C.B
L801
TP2
2
3
< CD SECTION >
1. Focus Bias Adjustment Make the focus bias adjustment when replacing and repairing the optical block.
Oscilloscope (DC range)
EYE PATTERN must be CLEAR and MAX VOLT / DIV: 200mV TIME / DIV: 0.5µs MAX
0V
+
TP3 (RF) TP4 (VREF)
< TAPE RECORDER SECTION >
2. Bias Adjustment � Test tape: TTA-630 � Test Point: TP2 � Adjustment location: L801 � Method: L801 .............................................................. 85kHz±2kHz 3. Azimuth Adjustment Condition: � Test tape: TTA-320 � Test point: PHONE JACK � Adjustment location: Azimuth adjustment screw Method: Play back the test tape and adjust the screw so that the output is maximum.
-
1) Connect an oscilloscope to the test point TP3 (RF) and TP4 (VREF). 2) Turn on the power switch. 3) Insert test disc TCD-782 (YEDS-18) and play back the second composition. 4) Adjust SFR430 so that RF signal of the test point TP3 (RF) is MAX and CLEAREST.
� 24 �
|
|
 |
> |
|
|
Parse Time: 0.193 - Number of Queries: 128 - Query Time: 0.042