Who's Online
There currently are 6039 guests and 4 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Good quality. Quick service. I recommend to everyone.
;
Very good quality scan of the document. I am very pleased with what I got.
;
PDF Contains
Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217.
It is the actual Service Manual for SQ10
;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
;
Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit.
regards: Nick
3-3. AUTO SEQUENCE Adjustment (EFB/IVR/FOCUS AGC/TRACKING AGC adjustment)
Test disc: MDW-60. TGYS-1 When adjusting MO disc 1) Insert the test disc MDW-60. 2) Press the 9 button to display �ALL SV OFF�. 3) When the �EDIT� button is pressed, �AUTO ADJ� is displayed. When the adjustment is completed, �DONE� is displayed. (When �FAILED� appears, it means that the adjustment has failed.) 4) Press 9 button to display �ALL SV OFF�. Note: 1. If a test disc is dirty or has scratches, the complete adjustment may be not performed. Be sure to use a clean disc. 2. When adjusting the MO disc, the pre-recorded data on the MO disc is erased partly because WRITE POWER is on. Use an exclusive disc for adjustment. How to check IVR, EFB, and focus/tracking/sled gain. 1 Move the pick up to the center with 6 button and 5 button. 2 Press the MD 2 button to display �FOCUS ON!�. 3 Press the �ENTER� button to turn on �ALL SV ON�. 4 Press the 9 button, and press the �DISP� button twice. Check that value of the display �IV$**: EF$ ��� is within the specifications shown below. �**� ............................... 13-17 ���� ............................. 09-12 5 Repress the �DISP� button. Check that value of the display �Gf**t##s33� is within the range shown below. �**� ............................... 20-40 �##� ............................... 15-35 �33� ............................. 15-35 6 When the adjustment is completed, press the 9 button to display �ALL SV OFF�. When adjusting PIT disc 1) Insert the test disc TGYS-1. 2) Press the 9 button to display �ALL SV OFF�. 3) When the �EDIT� button is pressed, �AUTO ADJ� is displayed. When the adjustment is completed, �DONE� is displayed. (When the �FAILED� appears, it means that the adjustment has failed.) 4) When the adjustment is completed, press the 9 button to display �ALL SV OFF�. How to check IVR, EFB, and focus/tracking/sled gain Perform the same operations as the MO disc check. The data on the display must be within the following range. �IVR� ............................ 14-19 �EFB� ........................... 09-12 �Focus gain� ................. 2A-45 �Tracking gain� ............. 20-40 �Sled gain� .................... 20-40
3-4. Error Rate Check (PIT disc)
1) 2) 3) 4) 5) 6) 7) Insert the test disc TGYS-1. Move the pick up to the center with 6 button and 5 button. Press the �TAPE 1 2� button to display �SELECT PIT�. Press MD 2 button to display �FOCUS ON!�. Press the �ENTER� button to display �ALL SV ON�, and press the �DISP� button to display �Er00** 0000�. Check the value of ** is �30� or less. When the adjustment is completed, press the 9 button to display �ALL SV OFF�.
3-5. Record/Playback Error Rate Check (MO disc)
1) 2) 3) 4) 5) 6) 7) Insert the test disc MDW-60. Move the pick up to the center with 6 button and 5 button. Press the �TAPE 1 2� button to display �SELECT GRV�. Press the �VOLUME DOWN� button to display �REC Analog�. Press the MD 2 button to display �FOCUS ON!�. Press the �VOLUME DOWN� button after pressing the �ENTER� button to display �ALL SV ON�. When the �MD REC� button is repressed, the OWH moves. The recording starts from the 600 cluster. Then the display changes from �ALL SV ON� to �ADR**C##S�. 8) After recording of about 15 seconds, press the 9 button to display �ALL SV OFF�. 9) Press the �VOLUME UP� button to move up the OWH.