Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Impressively thorough. Even the simple operators manual helped me "fix" one of the 2 CD players in the unit. This unit reads CD's from the top so they should be installed in the magazines "upside down" from typical CD players. The CD player service manual helped me unjam a stuck carriage because somebody transported the box laying down loaded with CD's. A little lens cleaning & the player now works well! Thanks for you help at a great price! Joe
 ;
I was skeptical at first but later found the manual to be good quality for the price. It took a couple hours to receive the email with the download link, well worth the wait. Thanks.
 ;
very helpful, I could not have cleaned motherboard and replaced the main fan without it
 ;
Good manual, schematics nice and clear with good quality scanning. Woul dhave been nice to have immediate access after purchasing though.
 ;
I was very glad recieving the service manal from You. Manuals were delivered promptly and were correct as advertised. A complete and very usefull service manual with all details. Thank you!
ELECTRICAL ADJUSTMENT-4/4 (K, EZ MODEL)
< TUNER SECTION >
1. FM VT Check Settings: � Test point: TP4 Method: Set to FM 87.5MHz, 108.6MHz and check that the test point is more than 0.5V (87.5MHz) and less than 8.0V (108.6MHz). 2. FM TRACKING Check Settings: � Test point: TP8 (Lch) TP9 (Rch) Method: Set to FM 98.0MHz and check that the test point is less than 13dBµV. 3. DC Balance Adjustment Settings: � Test point: TP5, TP6 � Adjustment location: L771 � Input level: 50dBµV Method: Set to FM 83.0MHz, 98.0MHz and adjust L771 so that the voltage between TP5 and TP6 becomes 0V±0.04V. 4. VT MW Check Settings: Test point: TP4 Method: Set to AM 1602kHz, 531kHz and check that the test point is more than 0.6V (531kHz) and less than 8.0V (1602kHz). 5. AM IF Adjustment Settings: � Test point: TP8 (Lch) TP9 (Rch) � Adjustment location: L772 Method: Set to MW 999kHz, 1000kHz and adjust L772 so that the Wave to maximum. 6. MW Tracking Adjustment Settings: � Test point: TP8 (Lch) TP9 (Rch) � Adjustment location: L981 Method: Set to MW 999kHz, 1000kHz and adjust L981 so that the test point is less than 58dBµV and becomes maximum. After adjust, lock it with PARAPFIN. 7. LW Tracking Adjustment Settings: � Test point: TP8 (Lch) TP9 (Rch) � Adjustment location: L941 (Low) TC942 (Hight) Method: Set to LW 144kHz, 290kHz and adjust L941, TC942 so that the test point is less than 70dBµV(low), 66dBµV(hight) . After adjust, lock it with PARAPFIN.
< DECK SECTION >
8. Tape speed Adjustment Settings: � Test tape: TTA-100 � Test point: PHONES JACK (J201) � Adjustment location: SFR1 Method: Play back the test tape and adjust so that the output frequency is 3000Hz ±30Hz. 9. Azimuth Adjustment Settings: � Test tape: TTA-320 � Test point: PHONES JACK (J201) � Adjustment location:Azimuth adjustment screw Method: Play back the test tape and adjust so that the output is maximum. 10. REC Bias Adjustment Settings: � Test tape : TTA: 602 � Test point: JW222 + JW221 � Adjustment location: L331 Method: Rec play the test tape and adjust so that the test point frequency is 83kHz±0.5kHz.
< CD SECTION >
11. CD Focus BIAS Adjustment Settings: � Test Disc: TCD-782 � Test point: TP1 + Vref � Adjustment location: SFR530 Method: Play back the test CD track 2 and adjust so that the output level is DC 0mV±10mV.
-33-
|
|
 |
> |
|