Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I PURHASED THIS PRODUCT BECAUSE I WAS HAVING PROBLEMS WITH MY CDR20 HARMAN KARDON RECORDER. WHICH I PURCHASED NEW 12 YEARS AGO. AFTER REVIEWING THE MANUAL, I WAS ABLE TO ADJUST THE TENSIONER IN THE SYSTEM. WORKS LIKE A CHAMP!.
SAVED ME AT LEAST 100.00 WHICH WAS WHAT A SERVICE REPAIR STATION WANTED. GREAT MANUAL EASY TO READ. SPECIALLY AFTER I PRINTED THE PAGES WHICH DEALT WITH MY RECORDER. THANKS A LOT!!!!!!!!
 ;
You can fully trust on this one!
All the schematics are very crear an in one piece per page
 ;
I have never bought a service manual which is as competely readable as this althogh it was a scanned pdf. Thank you for this succesful manual also cheaper than other sites.
 ;
Thanks for a very good and readable servicemanual. Just what I needed as a "dinosaur technician". I really recommmend this site and will come back.
Åsbjörn
 ;
The manual I purchased was just what I needed. I was glad to find a site where I can find so many manuals on a wide variety of products.
CSD-XD55 SECTION 4 MECHANICAL ADJUSTMENTS
PRECAUTION 1. Clean the following parts with a denatured-alcohol-moistened swab : record/playback head pinch roller erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. (Do not bring the head magnetizer close to the erase head.) 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the rated power supply voltage (9V) unless otherwise noted. Torque Measurement
Mode FWD Torque meter CQ-102C Meter reading 2.95 � 6.86 mN � m (30 � 70 g � cm) (0.42 � 0.97 oz � inch) FWD Back Tension CQ-102C 0.15 � 0.53 mN � m (1.5 � 5.5 g � cm) (0.021 � 0.076 oz � inch) more than 5.88 mN � m CQ-201B (more than 60 g � cm) (more than 0.83 oz � inch) more than 5.88 mN � m (more than 60 g � cm) (more than 0.83 oz � inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
TAPE SECTION 0 dB = 0.775 V
� Standard Output Level
Output terminal load impedance output signal level HP OUT 32 � 0.25 V (�10 dB)
� Test Tape
Type WS-48A Signal 3 kHz, 0 dB Used for tape speed adjustment
Tape Speed Adjustment
Procedure: Mode: playback Adjust so that the value on the digital frequency counter is 3,000 Hz.
FF
test tape WS-48A (3 kHz, 0 dB) 32 � set
digital frequency counter
REW
CQ-201B
i jack (J321)
Tape Tension Measurement
Mode FWD Tension meter CQ-403A Meter Reading more than 100 g (more than 3.53 oz)
Specification Value:
Digital frequency counter 2,940 to 3,060 Hz
Adjust so that the frequency at the beginning and that at the end of tape winding are between 2,970 to 3,030 Hz. Adjustment Location:
Tape speed adjustment control inside motor
14
|
|
 |
> |
|