Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
Pioneer CDXP23S is an old model and has been top useful for me to find this Manual. CD Player is still repaired.
 ;
Inventory (Stock): a rather extensive list of service manuals, which are hard to find, especially 15+ yrs old.
Pricing: very reasonable.
Delivery/Response: Very Prompt delivery of product: Placed order and received download access within 1.5hrs.
Service Manual: a rather complete OEM service manual (15.5MB pdf file size). Scan quality was very good, accept for a few circuit board diagrams that were dark; Zooming, however, clarified the image. Has the required information for servicing the LD Player.
 ;
Perfect copy of a necessary document and my Sonic Modulator is repaired!
 ;
Excellent replacement for original Manual. Worth every cent ! I am totally satisfied!
9.1.
9.1.1.
Indoor Unit
HOW TO FIX INSTALLATION PLATE 9.1.2. TO DRILL A HOLE IN THE WALL AND INSTALL A SLEEVE OF PIPING
The mounting wall is strong and solid enough to prevent it from the vibration.
1. Insert the piping sleeve to the hole. 2. Fix the bushing to the sleeve. 3. Cut the sleeve until it extrudes about 15 mm from the wall.
Caution
When the wall is hollow, please be sure to use the sleeve for tube ass�y to prevent dangers caused by mice biting the connecting cable.
The centre of installation plate should be at more than 550 mm at right and left of the wall. The distance from installation plate edge to ceiling should more than 67 mm. From installation plate left edge to unit�s left side is 47 mm. From installation plate right edge to unit�s right is 73 mm. : For left side piping, piping connection for liquid should be about 126 mm from this line. : For left side piping, piping connection about 174 mm from this line. : For left side piping, piping connection about 984 mm from this line.
4. Finish by sealing the sleeve with putty or caulking compound at the final stage.
#
1. Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the concrete wall, consider using anchor bolts.) � Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge 2. Drill the piping plate hole with ø70 mm hole-core drill. � Line according to the arrows marked on the lower left and right side of the installation plate. The meeting point of the extended line is the centre of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole centre is obtained by measuring the distance namely 150 mm and 125 mm for left and right hole respectively. � Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side.
9.1.3.
INDOOR UNIT INSTALLATION
1. For the right rear piping
2. For the right and right bottom piping
3. For the embedded piping
19
|
|
 |
> |
|