Description of PANASONIC CUC24BKP6 Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file after You purchase it.

Owner's Manual ( sometimes referred to as User's Guide or User's Manual ) contains information on how to use Your device. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 IS70-49VT BLAUPUNKT Owner's Manual by Alexey Baikov;
Хорошее качество сканирования. Мануал пришел часов эдак через 12. В целом доволен.
 DV-09/KU/CA PIONEER Owner's Manual by james harroun;
Fantastic quality and impressive delivery time. Based on this manual, I recommend this service without hesitation! Five Stars for certain.
 SA-GX505 TECHNICS Owner's Manual by KEVIN TODD;
Was happy to find the complete owners manual... It's all in there, just like the original...
 RS-BX828 TECHNICS Owner's Manual by Mieczyslaw Wojdyla;
Thanks for offering this item at such a good price. Proved handy in identifying the part I was looking for my set.
 HS-521V MITSUBISHI Owner's Manual by Wolfgang Molt;
Thr Video Recorder i have is quiet Old and the Producer could Not help me. So i w as very glad to find an offer for the owners Manual for a very fair Price.a I obtained the original Manual very quick and I am happy to have it now.

Text excerpt from page 9 (click to view)
CARE AND MAINTENANCE
I Cleaning the Indoor Unit and Remote Control
� Wipe gently with a soft, dry cloth. � Do not use water hotter than 104�F or polishing fluid to clean the unit.

ENGLISH

I Air Purifying Filters

I Pre-season Inspection
G Is the discharged air cold? Operation is normal if 15 minutes after the start of operation, the difference between the air intake and outlet vents temperature is:COOL � 14°F or above

1
Raise the front panel

I Cleaning the Air Filter
(Recommendation:- If the unit is operated in a dusty environment, clean the filters every two weeks, continuous use of this dirty filters will reduce cooling efficiency) Remove dirt using a vacuum cleaner. Wash back of the air filter with water. If badly soiled, wash it with soap or a mild household detergent. Let it dry and reinstall it. Be sure the �FRONT� mark is facing you. * Damaged air filter. Consult the nearest authorized dealer. Part No.: CWD001049. � Do not use benzene, thinner, scouring powder or clothes soaked in caustic chemical to clean the unit.

Solar Refreshing Deodorizing Filter Catechin Air Purifying Filter

G Are the air intake or outlet vents of the indoor or outdoor units obstructed? G Are the remote control batteries weak? If the remote control display appears weak, replace the batteries.

1 2 3 4

2

Remove the air filters

G Solar Refreshing Deodorizing Filter � Used to remove unpleasant odour and deodorize the air in the room. � Reusable. � Vacuum, place under direct sunlight for 6 hours and fit it back in place. (Recommended : every 6 months) G Catechin Air Purifying Filter � The filter is coated with catechin to prevent growth of bacteria and viruses. � Reusable. � Vacuum and fit it back in place (Recommended : every 6 months) � Recommended to change these filters every 3 years. Do not reuse damaged filters. Consult the nearest authorized dealer to purchase a new filter. Catechin Air Purifying Filter No.: CZ-SF70P Solar Refreshing Deodorizing Filter No.: CZ-SFD70P If you operate the air conditioner with dirty filters:� Air is not purified � Cooling capacity decreases � Foul odour is emitted

I When the Air Conditioner is Not Used for an Extended Period of Time 1 To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using:FAN operation

I Cleaning the Front Panel
(Must be removed before washing)

1 2

Raise the front panel higher than the horizontal and pull to remove it. Gently wash with water and a sponge. � Do not press the front panel too hard when washing. � When use kitchen cleaning fluid (neutral detergent), rinse throughly. � Do not dry the front panel under direct sunlight. To fix the front panel, raise the front panel horizontally, match the protruding portion on the indoor unit to the fulcrum and push into place.

2

3

Turn off the power supply and unplug. Note: If the unit is not switched off by the remote control, it will start operating when you plug in (because the unit is equipped with Auto Restart Control). Remove the remote control batteries.

3

I Recommended Inspection
� After used over several seasons, the unit will become dirty and thus decreases the unit�s performance. Depending on the operation conditions, a dirty unit may produce odour and dust may pollute dehumidification system. Therefore, a seasonal inspection is recommended in addition to regular cleaning. (Consult an authorized dealer).

� Fulcrum

Protruding portion on indoor unit