Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit.
regards: Nick
 ;
This was super service.Ordered this manual and was reading the download an hour later
 ;
as always, rapid and efficient, very good and clear prints
details clearly visible keep going this way!!!!!!
CS-C9CKPG CU-C9CKP6G / CS-C12CKPG CU-C12CKP6G
11.1.4. Balance refrigerant of the 2-way, 3-way valves
(Gas leakage)
Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the open position. 2. Connect the charge set to the 3-way valve�s service port. � Leave the valve on the charge set closed. � Connect the charge hose with the push pin to the service port. 3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge indicates 0.5 to 1 kg/cm2G (0.05 to 0.1 MPa) . � If there is no air in the refrigeration cycle [the pressure when the air conditioner is not running is higher than 1 kg/cm2G (0.1 MPa)], discharge the refrigerant until the gauge indicates 0.5 to 1 kg/cm2G (0.05 to 0.1 MPa). If this is the case, it will not be necessary to apply a evacuation. � Discharge the refrigerant gradually; if it is discharged too suddenly, the refrigeration oil will be discharged.