There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
CVP09FR
29.Remove wiring connectors of the compressor cord by using longnose pliers.(3 parts) Then turn the band to the direction, as shown in below figure. CAUTION: RETURN THE BAND TO THE ORIGINAL DIRECTION WHEN RE-ASSEMBLYING.
CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR AND RUNNING CAPACITOR BEFORE TOUCHING THESE CAPACITORS OR OTHER COMPONENTS OR WIRING. 30.Unscrew 2 screws holding the control box. Remove the control box from the unit.
33.Move the band to the direction shown in below figure (approx.11/ 16"). Then removed the drain hose B.
34.Unscrew the screw holding the lead wire. 31.Unscrew 6 screws holding the casing cover. Remove the casing cover from the unit.
35.Turn the band, as shown in below figure. CAUTION: RETURN THE BAND TO THE ORIGINAL DIRECTION WHEN RE-ASSEBLYING. 32.Unscrew 4 screws holding the orifice. Remove the orifice from the unit. Move the band to the direction of the arrow(approx.11/16"), and removed the drain hose A.