Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was very glad recieving the service manal from You. Additionaly very fast. Extremaly nice servicing. Thanks very mach! Now my GX-220 working better, than it was made. Alexander from Moscow, Russia/
 ;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
 ;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
 ;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
CX-692
3. MECHANISM DESCRIPTIONS
- Inserting the Magazine
1. Inserting the magazine while countering the spring force of the EJECT lever , the lock arm will slide along the groove on the reverse side of the magazine and lock into place(due to the torsion spring on the reverse side of the lock arm).
2. The magazine lock is detected when the sensor arm moves along the EJECT lever cam section and presses against the MAG switch(S301) located on the CD core unit. Initially , the sensor arm is held by the cam section of the EJECT lever until the magazine lock arm is pushed off by the groove on the reverse side of the magazine. When the lock arm is pushed off the cam section is released , but is held again by the lock arm. When the magazine lock is released, the sensor arm presses the MAG switch(S301).
Fig. 29 When the magazine is not inserted EJECT lever cam MAG switch (S301) Detection arm When the magazine is not inserted
- Elevation Operation
The drive operation is the same as the CX-652. (See service manual CX-652:CRT1857)
- Elevation Detection
When the rear lever is driven the front lever and sensor lever are also driven via the jointed arm. The voltage is detected, and drive initiated, when the knob of the linear position sensor(slide volume:VR801) enters the U-shaped groove of the sensor lever. Stop Lock arm Moves along the groove in the magazine. Fig. 30
Stop
Fig. 31
24
|
|
 |
> |
|