Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the 2nd time I download manuals from this website and I can say it's what I was expecting. It contains schematic, layout (decent quality), short description, parts and dissasembly instructions. I recomend it for anyone who wants to repair/modify this device.
 ;
Very useful Service Manual! With it I was able to identify the damaged pots in my old amplifier, purchase the adequate replacements and make myself the repair.
I have again my old amplifier, still a very good one that I will keep for as many years as I can!
Thanks to Owner Manuals!
 ;
Good price for the manual and easy to locate on the site and download. Plus, just like the original. Thanks a lot.
 ;
Genuine Service Manual. Link was available in less then an hour or so. Service Manual contains assembly, PCB layout, complete circuit diagram, Components list etc
 ;
Great and very well scanned Service Manual, also very fast download - Recomended !
CX-JS5 SECTION 5 ELECTRICAL ADJUSTMENTS
CD SECTION
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. Note: Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
level : 1.0 ±0.3Vp-p
S-CURVE CHECK
Oscilloscope BD board
Connecting Location: BD board
TP(FE) TP(VC)
� BD Board (Conductor side) �
Procedure : 1. Connect an oscilloscope to TP (FE) and TP (VC). 2. Turn the power on. 3. Load a disc (YEDS-18) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 4. Confirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 3 ± 0.5 Vp-p.
S-curve waveform symmetry
TP (RF)
A within 3 ±0.5Vp-p B
TP (VC) TP (FE)
Note: � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
IC721
RF LEVEL CHECK
oscilloscope BD board TP(RF) TP(VC)
Procedure : 1. Connect an oscilloscope to TP (RF) and TP (VC). 2. Turn the power on. 3. Load a disc (YEDS-18) and playback. 4. Confirm that oscilloscope waveform is clear and check if RF signal level is correct or not.