The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.
CX-JS77 SECTION 5 ELECTRICAL ADJUSTMENTS
CD SECTION
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, 2. 3. 4. check each item in order given. Use YEDS-18 (3-702-101-01) unless otherwise indicated. Use an oscilloscope with more than 10M� impedance. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
level : 1.3 ± 0.3 Vp-p
S-CURVE CHECK
Oscilloscope CD board TP(FE) TP(VC)
� CD BOARD (Conductor Side) �
Procedure : 1. Connect an oscilloscope to TP (FE) and TP (VC) on the CD board. 2. Press the I/1 button to turn the power ON. 3. Load a disc (YEDS-18) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 4. Confirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 3 ± 0.5 Vp-p.
S-curve waveform symmetry
TP (VC)
TP (FE) IC101
A within 3 ± 0.5 Vp-p B
TP (RFACO)
Note: � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
Connecting Location: CD board
RFAC LEVEL CHECK
oscilloscope CD board TP(RFACO) TP(VC)
Procedure : 1. Connect an oscilloscope to TP (RFACO) and TP (VC) on the CD board. 2. Press the I/1 button to turn the power ON. 3. Load a disc (YEDS-18) and playback. 4. Confirm that oscilloscope waveform is clear and check if RFAC signal level is correct or not.
Note: Clear RFAC signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
Connecting Location: CD board
21
21
|
|
 |
> |
|