Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
 ;
We received the manual in a timely manner and it was exactly what we were expecting.
 ;
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
 ;
Very good scanning quality. All schematics are very legible. Worth every cent !
 ;
Excellent quality, very quick download turnaround, will definately use again.
Dolby®-Pegeleinstellung
Me�punkte ............................... MP 1377, MP 1378 Signalquelle ............................. Dolby®-Testcassette 400 Hz / 200 nWb/m Abgleichelemente .................... R 1241, R 1261 Spezifikation ............................ 450 mV ± 27 mV 1. Schalten Sie die Dolby®-Funktion aus. 2. Legen Sie die Dolby®-Testcassette in den Cassettenschacht ein, und starten Sie die Wiedergabe. 3. Stellen Sie mit R 1241 einen Pegel von 450 mV ± 27 mV an MP 1277 ein. Stellen Sie mit R 1261 einen Pegel von 450 mV ± 27 mV an MP 1278 ein.
* Rauschunterdrückungssystem unter Lizenz von Dolby Laboratories hergestellt. Das Wort Dolby und das Symbol des doppelten D sind die Markenzeichen von Dolby Laboratories.
Dolby® Adjustment
Measuring points ..................... MP 1377, MP 1378 Signal source ........................... Dolby® test cassette 400 Hz / 200 nWb/m Alignment elements ................. R 1241, R 1261 Specification ............................ 450 mV ± 27 mV 1. Switch Dolby® off. 2. Insert the Dolby® test cassette into the cassette compartment. Start tape play. 3. Use R 1241 to adjust a level of 450 mV ± 27 mV at MP 1277. Use R 1261 to adjust a level of 450 mV ± 27 mV at MP 1278.
* Noise reduction system manufatured under the licence of Dolby Laboratories. The Dolby logo and the double D Dolby symbol are registered trademarks of Dolby Laboratories.
Logik-Platte Logic board
PL 0312 A05
R1261
R1241
6 8 1
1377
4 1
8
1
D1140
9 16
D1250
9 11 16
D1350
5 8
1378
R1261 R1241
- 11 -
|
|
 |
> |
|