Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
got exactly what i ordered in a very timely manner. will use again for other manuals
 ;
I'm happy. Good quality. Very helped me with my work..............................
 ;
This is the second Manual I have ordered from owner-manuals, I give it five stars because it is exactly what I expected given the age of the equipment. So the contents look a bit aged and the pictures a bit grainy, it fulfills my needs and I am glad I can still get hold of them.
 ;
thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
 ;
I do not have very much to say.
The price is quite covenient, delivery was better as promised (about 12 ours, against the specified 24 hours if I remember well), and the quality of the PDF is more than acceptable.
The Service Manual of Sansui R30 itself is also satisfactory: good graphic for schematics and layouts, simple and well structured.
Giovanni Bianchi
Precautions for Checking Emission of Laser Diode Laser light of the equipment is focused by the object lens in the optical pick-up so that the light focuses on the reflection surface of the disc. Therefore, be sure to keep your eyes more then 30cm apart from the object lens when you check the emission of laser diode. Laser Diode Checking Methods During normal operation of the equipment, emission of the laser diode is prohibited unless the upper panel is closed while turning ON the S801 (push switch type). The following two checking methods for the laser diode are operable. Method-1 (In the service mode or normal operation) : Emission of the laser diode is visually checked. 1. Open the upper lid. 2. Push the S801 as shown in Fig. 1 . 3. Check the object lens for confirming normal emission of the laser diode. If not emitting, there is a trouble in the automatic power control circuit or the optical pick-up. During normal operation, the laser diode is turned ON about 2.5 seconds for focus searching.
6. Check that the current value is within the following range. +5 � Current value of the label -11 mA(25°C) Variation by temperature : 0.4mA / °C Current increases with temperature increased. Current decreases with temperature decreased. If the current is more than the range above, there is a trouble in the automatic power control circuit or the laser diode is in deterioration. If less than the range, a trouble exists in the automatic power control circuit or the optical pick-up.
[MAIN BOARD] (Conductor side)
S801
Fig.1 Method to push S801
Method-2 (In the service mode or normal operation) : Check the value of current flowing in the laser diode. 1. Remove the upper panel. 2. Read the current printed on the rear side of the optical pick-up. (Print on the rear side of the optical pick-up)
AC2211397 current value A : less than 48 mA year month date shift No. line No. version
digital voltmeter TP506 TP547
TP547
IC501
3. Connect a level meter as shown in Fig. 2 4. Press the ^ key. 5. Calculate the current value by the reading of the digital voltmeter Reading of the tester (V) ÷ 4.7 ( � ) = current value (A) (Example) Reading of the digital voltmeter of 0.2256 V : 0.2256 V ÷ 4.7 � = 0.048 (A) = 48 mA
TP506
Fig. 2 Digital Voltmeter Connecting Location
�3�
|
|
 |
> |
|